Interestingly, my X310 front panel LED occasionally, very briefly shows red too. Maybe the schematic isn’t current with what is actually used in the unit these days(?).
Regards, Joe > On Mar 7, 2019, at 3:36 PM, Marcus Müller via USRP-users > <usrp-users@lists.ettus.com> wrote: > > So that's built on an X3x0 platform. As said, no, the link leds really > just display link status, nothing about the data. > Also, when you look at the schematic of the X300, PDF [1] page 13, > you'll find no red LED – only green and yellow, so I must admit I'm a > bit confused about what you witnessed? > > Best regards, > Marcus > > [1] http://files.ettus.com/schematics/x300/x3xx.pdf > On Thu, 2019-03-07 at 09:56 +0000, Koyel Das (Vehere) wrote: >> I am using USRP 2955 R >> >> Koyel Das >> Senior – Product Engineer >> Vehere | Proactive Communications Intelligence & Cyber Defence >> M: +919051132173 | T: +91 33 40545454 | F: +91 33 40545455 | W: >> www.vehere.com >> >> >> >> Vehere is the proud recipient of the Fastest Growing Technology >> Company Awards in India & Asia since 2012! >> >> The content of this e-mail is confidential and intended solely for >> the use of the addressee. The text of this email (including any >> attachments) may contain information, which is proprietary and/or >> confidential or privileged in nature belonging to Vehere Interactive >> Pvt Ltd and/or its associates/ group companies/ subsidiaries. If you >> are not the addressee, or the person responsible for delivering it to >> the addressee, any disclosure, copying, distribution or any action >> taken or omitted to be taken in reliance on it is prohibited and may >> be unlawful. If you have received this e-mail in error, please notify >> the sender and remove this communication entirely from your system. >> The recipient acknowledges that no guarantee or any warranty is given >> as to completeness and accuracy of the content of the email. The >> recipient further acknowledges that the views contained in the email >> message are those of the sender and may not necessarily reflect those >> of Vehere Interactive Pvt Ltd. Before opening and accessing the >> attachment please check and scan for virus. WARNING: Computer viruses >> can be transmitted via email. The recipient should check this email >> and any attachments for the presence of viruses. The company accepts >> no liability for any damage caused by any virus transmitted by this >> email. >> From: Marcus Müller <marcus.muel...@ettus.com> >> Sent: Thursday, March 7, 2019 3:21:40 PM >> To: Koyel Das (Vehere); 'USRP-users@lists.ettus.com' >> Subject: Re: [USRP-users] link led colour >> >> The link LEDs on our USRPs don't indicate validness of data. It's >> highly likely this is normal. What USRP are you using? >> >> Best regards, >> Marcus >> >> On Wed, 2019-03-06 at 05:05 +0000, Koyel Das (Vehere) via USRP-users >> wrote: >>> Hi, >>> >>> When I am receiving data using ethernet my link LED is orange most >> of >>> the times and blinking to red for momentarily, which is not so >>> noticeable. Am I receiving wrong data? It is not turning green. >>> >>> Regards, >>> Koyel >>> >>> Koyel Das >>> Senior – Product Engineer >>> Vehere | Proactive Communications Intelligence & Cyber Defence >>> M: +919051132173 | T: +91 33 40545454 | F: +91 33 40545455 | W: >>> www.vehere.com _______________________________________________ USRP-users mailing list USRP-users@lists.ettus.com http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com