On 11/10/2017 01:11 AM, Bakshi, Arjun via USRP-users wrote:

I'm observing an unstable phase when I'm transmitting and receiving a constant value over a wire. Is that normal, or is something wrong with my HW or configuration?


I assumed that since the channel is fixed, and USRPs are synced, that I'd see a constant phase.


I'm using 2xN210s with WBX boards in them, and a MIMO cable to connect/sync them. Sampling rate is 2Msps. Flow GRC and image attached.


Thank you,


AB



_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com
What gain values are you using on each end?

I hope that you have significant attenuation in the cable that you're using to connect the TX to RX.


_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

Reply via email to