But when I am setting so, I see only the LED of one daughter board glowing. So it still receiving data from one daughter board. Please help me with it.
BR Snehasish ________________________________ From: Julian Arnold <jul...@elitecoding.org> Sent: Monday, August 7, 2017 4:46:14 PM To: Snehasish Kar; usrp-users@lists.ettus.com Subject: Re: [USRP-users] Help with rx_multi_sample Hey Snehasish, it should be A:0 B:0 instead of 0:A 0:B. E.g.: usrp->set_rx_subdev_spec(uhd::usrp::subdev_spec_t("A:0 B:0")); Cheers, Julian On 08/07/2017 12:39 PM, Snehasish Kar via USRP-users wrote: > > Hello > > > I tried setting subdev to subdev("0:A 0:B") as described in the > example "rx_multi_samples" . But its giving me an error saying Invalid > daughter-board frontend name : A. I am using NI USRP 2954R. > > > Please help me with it. > > > BR > > Snehasish > > > > > _______________________________________________ > USRP-users mailing list > USRP-users@lists.ettus.com > http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com -- Julian Arnold, M.Sc. Institute for Networked Systems RWTH Aachen University Kackertstrasse 9 52072 Aachen Germany
_______________________________________________ USRP-users mailing list USRP-users@lists.ettus.com http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com