OK, did some testing with MVAPICH and everything is normal so this is
clearly with OMPI. Is there anything that I should try?

Thanks,

Yong Qin

On Mon, Mar 6, 2017 at 11:46 AM, Yong Qin <yong....@gmail.com> wrote:

> Hi,
>
> I'm wondering if anybody who has done perf testing on Mellanox EDR with
> OMPI can shed some light here?
>
> We have a pair of EDR HCAs connected back to back. We are testing with two
> dual-socked Intel Xeon E5-2670v3 (Haswell) nodes @2.30GHz, 64GB memory. OS
> is Scientific Linux 6.7 with kernel
> 2.6.32-642.6.2.el6.x86_64, vanilla OFED 3.18-2. HCAs are running the
> latest FW. OMPI 2.0.2.
>
> OSU bandwidth test only delivers ~5.5 GB/s at 4MB message size, latency is
> ~2.7 us at 0B message size. Both are far behind the claimed values. RDMA
> perf on the same set up was not too shabby - bandwidth ~10.6 GB/s, latency
> ~ 1.0 us.
>
> So I'm wondering if I'm missing anything in the OMPI setup that causes
> such a huge delta? OMPI command was simplely: mpirun -np 2 -H host1,host2
> -mca btl openib,sm,self osu_bw
>
> Thanks,
>
> Yong Qin
>
_______________________________________________
users mailing list
users@lists.open-mpi.org
https://rfd.newmexicoconsortium.org/mailman/listinfo/users

Reply via email to