Hi, I'm wondering if anybody who has done perf testing on Mellanox EDR with OMPI can shed some light here?
We have a pair of EDR HCAs connected back to back. We are testing with two dual-socked Intel Xeon E5-2670v3 (Haswell) nodes @2.30GHz, 64GB memory. OS is Scientific Linux 6.7 with kernel 2.6.32-642.6.2.el6.x86_64, vanilla OFED 3.18-2. HCAs are running the latest FW. OMPI 2.0.2. OSU bandwidth test only delivers ~5.5 GB/s at 4MB message size, latency is ~2.7 us at 0B message size. Both are far behind the claimed values. RDMA perf on the same set up was not too shabby - bandwidth ~10.6 GB/s, latency ~ 1.0 us. So I'm wondering if I'm missing anything in the OMPI setup that causes such a huge delta? OMPI command was simplely: mpirun -np 2 -H host1,host2 -mca btl openib,sm,self osu_bw Thanks, Yong Qin
_______________________________________________ users mailing list users@lists.open-mpi.org https://rfd.newmexicoconsortium.org/mailman/listinfo/users