Hi Tim, Thank you very much for the detailed response. Yes, I am aware that PFC will kick in eventually and do a collateral damage while using async sends without configuring /Producer Window Size/.
However, I am not seeing that collateral damage when sending messages in batches with batch size > 1. Messages are enqueued continuously as though PFC is turned off until the /storeUsage/ limit is reached. -- View this message in context: http://activemq.2283324.n4.nabble.com/What-is-the-correct-way-to-throttle-ActiveMQ-producers-who-send-persistent-messages-in-batches-to-a--tp4701204p4701211.html Sent from the ActiveMQ - User mailing list archive at Nabble.com.