Hi Tim,

Thank you very much for the detailed response.
Yes, I am aware that PFC will kick in eventually and do a collateral damage
while using async sends without configuring /Producer Window Size/.

However, I am not seeing that collateral damage when sending messages in
batches with batch size > 1. Messages are enqueued continuously as though
PFC is turned off until the /storeUsage/ limit is reached.



--
View this message in context: 
http://activemq.2283324.n4.nabble.com/What-is-the-correct-way-to-throttle-ActiveMQ-producers-who-send-persistent-messages-in-batches-to-a--tp4701204p4701211.html
Sent from the ActiveMQ - User mailing list archive at Nabble.com.

Reply via email to