Hello Wencong,

Thank you for your valuable feedback and suggestions. I want to clarify
that reviewing existing methods in the ExecutionConfig is not directly
related to the proposal in this FLIP. The main focus of this FLIP is to
deprecate the specific method RuntimeContext#getExecutionConfig(). I
believe it is important to keep the scope of this FLIP limited. However,
your suggestion can certainly be considered as a separate FLIP in the
future.

Best regards,
Junrui

Wencong Liu <liuwencle...@163.com> 于2023年11月17日周五 22:08写道:

> Hello Junrui,
>
>
> Thanks for the effort. I agree with the proposal to deprecate the
> getExecutionConfig() method in the RuntimeContext class. Exposing
> the complex ExecutionConfig to user-defined functions can lead to
> unnecessary complexity and risks.
>
>
> I also have a suggestion. We could consider reviewing the existing
>  methods in ExecutionConfig. If there are methods that are defined
>  in ExecutionConfig but currently have no callers, we could consider
>  annotating  them as @Internal or directly removing them. Since
> users are no longer able to access and invoke these methods,
> it would be beneficial to clean up the codebase.
>
>
> +1 (non-binding).
>
>
> Best,
> Wencong
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
> At 2023-11-15 16:51:15, "Junrui Lee" <jrlee....@gmail.com> wrote:
> >Hi all,
> >
> >I'd like to start a discussion of FLIP-391: Deprecate
> >RuntimeContext#getExecutionConfig[1].
> >
> >Currently, the FLINK RuntimeContext is important for connecting user
> >functions to the underlying runtime details. It provides users with
> >necessary runtime information during job execution.
> >However, he current implementation of the FLINK RuntimeContext exposes the
> >ExecutionConfig to users, resulting in two issues:
> >Firstly, the ExecutionConfig contains much unrelated information that can
> >confuse users and complicate management.
> >Secondly, exposing the ExecutionConfig allows users to modify it during
> job
> >execution, which can cause inconsistencies and problems, especially with
> >operator chaining.
> >
> >Therefore, we propose deprecating the RuntimeContext#getExecutionConfig in
> >the FLINK RuntimeContext. In the upcoming FLINK-2.0 version, we plan to
> >completely remove the RuntimeContext#getExecutionConfig method. Instead,
> we
> >will introduce alternative getter methods that enable users to access
> >specific information without exposing unnecessary runtime details. These
> >getter methods will include:
> >
> >1. @PublicEvolving <T> TypeSerializer<T>
> >createSerializer(TypeInformation<T> typeInformation);
> >2. @PublicEvolving Map<String, String> getGlobalJobParameters();
> >3. @PublicEvolving boolean isObjectReuseEnabled();
> >
> >Looking forward to your feedback and suggestions, thanks.
> >
> >[1]
> >
> https://cwiki.apache.org/confluence/pages/viewpage.action?pageId=278465937
> >
> >Best regards,
> >Junrui
>

Reply via email to