On 09/01/2012 21:22, Zach Sadecki wrote:
> There are 2 locations in the power init code for the mx28 where IRQs are not 
> being cleared because incorrect methods to clear those bits were being used.  
> This was causing my board to get stuck waiting for POWER_CTRL_VDD5V_DROOP_IRQ 
> to clear.  Using the correct method to clear the IRQs fixes it.
> 
> Signed-off-by: Zach Sadecki <z...@itwatchdogs.com>
> Cc: Wolfgang Denk <w...@denx.de>
> Cc: Stefano Babic <sba...@denx.de>
> ---

Applied to u-boot-imx, thanks.

Best regards,
Stefano Babic

-- 
=====================================================================
DENX Software Engineering GmbH,     MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-0 Fax: +49-8142-66989-80  Email: off...@denx.de
=====================================================================
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot

Reply via email to