On 06.05.25 04:58, Tony Dinh wrote:
Remove DS109 board reset_misc() function. U-Boot generic reset is enough.

Signed-off-by: Tony Dinh <mibo...@gmail.com>

Reviewed-by: Stefan Roese <s...@denx.de>

Thanks,
Stefan

---

  board/Synology/ds109/ds109.c | 18 ------------------
  1 file changed, 18 deletions(-)

diff --git a/board/Synology/ds109/ds109.c b/board/Synology/ds109/ds109.c
index 4f397578182..f3a914cc515 100644
--- a/board/Synology/ds109/ds109.c
+++ b/board/Synology/ds109/ds109.c
@@ -97,24 +97,6 @@ int board_init(void)
        return 0;
  }
-/* Synology reset uses UART */
-#include <ns16550.h>
-#define SOFTWARE_SHUTDOWN   0x31
-#define SOFTWARE_REBOOT     0x43
-#define CFG_SYS_NS16550_COM2           KW_UART1_BASE
-void reset_misc(void)
-{
-       int b_d;
-       printf("Synology reset...");
-       udelay(50000);
-
-       b_d = ns16550_calc_divisor((struct ns16550 *)CFG_SYS_NS16550_COM2,
-                                  CFG_SYS_NS16550_CLK, 9600);
-       ns16550_init((struct ns16550 *)CFG_SYS_NS16550_COM2, b_d);
-       ns16550_putc((struct ns16550 *)CFG_SYS_NS16550_COM2,
-                    SOFTWARE_REBOOT);
-}
-
  #ifdef CONFIG_RESET_PHY_R
  /* Configure and enable MV88E1116 PHY */
  void reset_phy(void)

Viele Grüße,
Stefan Roese

--
DENX Software Engineering GmbH,      Managing Director: Erika Unter
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: s...@denx.de

Reply via email to