Hello Tom,
On 25.02.25 03:39, Tom Rini wrote:
Here's the latest report. Getting closer with the led change. I do wish
it was easier to test fixes here.
Yes...
---------- Forwarded message ---------
From: <scan-ad...@coverity.com>
Date: Mon, Feb 24, 2025, 5:05 PM
Subject: New Defects reported by Coverity Scan for Das U-Boot
To: <tom.r...@gmail.com>
Hi,
Please find the latest report on new defect(s) introduced to Das U-Boot
found with Coverity Scan.
1 new defect(s) introduced to Das U-Boot found with Coverity Scan.
2 defect(s), reported by Coverity Scan earlier, were marked fixed in the
recent build analyzed by Coverity Scan.
New defect(s) Reported-by: Coverity Scan
Showing 1 of 1 defect(s)
** CID 542488: Control flow issues (NO_EFFECT)
/drivers/led/led-uclass.c: 277 in led_get_function_name()
________________________________________________________________________________________________________
*** CID 542488: Control flow issues (NO_EFFECT)
/drivers/led/led-uclass.c: 277 in led_get_function_name()
271 return uc_plat->label;
272
273 /* Now try to detect function label name */
274 func = dev_read_string(dev, "function");
275 cp = dev_read_u32(dev, "color", &color);
276 // prevent coverity scan error CID 541279: (TAINTED_SCALAR)
CID 542488: Control flow issues (NO_EFFECT)
This less-than-zero comparison of an unsigned value is never true.
"color < 0U".
277 if (color < LED_COLOR_ID_WHITE || color >= LED_COLOR_ID_MAX)
278 cp = -EINVAL;
So I simply remove this check ... and add a comment that LED_COLOR_ID_WHITE
must be 0...
279
280 if (cp == 0 || func) {
281 ret = dev_read_u32(dev, "function-enumerator",
&enumerator);
282 if (!ret) {
----- End forwarded message -----
Send the fix, when CI succeeds:
https://dev.azure.com/hs0298/hs/_build/results?buildId=171&view=results
Thanks for the report.
bye,
Heiko
--