On 08/10/2024 16:36, Jonas Karlman wrote:
Hi Neil,
On 2024-10-08 14:58, Neil Armstrong wrote:
If the regulator is already enabled, this happens if the regulator
is set in regulator-always-on, regulator_set_enable() return -EALREADY.
Ignore the -EALREADY return since it's not an error.
Signed-off-by: Neil Armstrong <neil.armstr...@linaro.org>
---
drivers/video/meson/meson_dw_hdmi.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/video/meson/meson_dw_hdmi.c
b/drivers/video/meson/meson_dw_hdmi.c
index 587df7beb9b..ee219ce6ec4 100644
--- a/drivers/video/meson/meson_dw_hdmi.c
+++ b/drivers/video/meson/meson_dw_hdmi.c
@@ -419,7 +419,7 @@ static int meson_dw_hdmi_probe(struct udevice *dev)
if (!ret) {
ret = regulator_set_enable(supply, true);
- if (ret)
+ if (ret && ret != -EALREADY)
You could possible relax this further using something like:
ret = regulator_set_enable_if_allowed(supply, true);
if (ret && ret != -ENOSYS)
That way you only reach the error state when there is an error with
supply, for other states e.g. when supply is not found, DM_REGULATOR=n
or the regulator is already enabled will be treated as success (ret=0).
Nice, thanks for the suggestion :-)
Neil
Regards,
Jonas
return ret;
}
#endif
---
base-commit: 28dc47038edc4e93f32d75a357131bcf01a18d85
change-id: 20241008-u-boot-video-fix-hdmi-supply-already-on-e6a9af27b1eb
Best regards,