On 08/10/2024 16:36, Jonas Karlman wrote:
Hi Neil,

On 2024-10-08 14:58, Neil Armstrong wrote:
If the regulator is already enabled, this happens if the regulator
is set in regulator-always-on, regulator_set_enable() return -EALREADY.

Ignore the -EALREADY return since it's not an error.

Signed-off-by: Neil Armstrong <neil.armstr...@linaro.org>
---
  drivers/video/meson/meson_dw_hdmi.c | 2 +-
  1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/video/meson/meson_dw_hdmi.c 
b/drivers/video/meson/meson_dw_hdmi.c
index 587df7beb9b..ee219ce6ec4 100644
--- a/drivers/video/meson/meson_dw_hdmi.c
+++ b/drivers/video/meson/meson_dw_hdmi.c
@@ -419,7 +419,7 @@ static int meson_dw_hdmi_probe(struct udevice *dev)
if (!ret) {
                ret = regulator_set_enable(supply, true);
-               if (ret)
+               if (ret && ret != -EALREADY)

You could possible relax this further using something like:

   ret = regulator_set_enable_if_allowed(supply, true);
   if (ret && ret != -ENOSYS)

That way you only reach the error state when there is an error with
supply, for other states e.g. when supply is not found, DM_REGULATOR=n
or the regulator is already enabled will be treated as success (ret=0).

Nice, thanks for the suggestion :-)

Neil


Regards,
Jonas

                        return ret;
        }
  #endif

---
base-commit: 28dc47038edc4e93f32d75a357131bcf01a18d85
change-id: 20241008-u-boot-video-fix-hdmi-supply-already-on-e6a9af27b1eb

Best regards,