On 01/20/2011 09:46 AM, Stefano Babic wrote:
> From: Anatolij Gustschin <ag...@denx.de>
> 
> The MXC SPI driver didn't calculate the SPI clock up to
> now and just used highest possible divider 512 for DATA
> RATE in the control register. This results in very low
> transfer rates.
> 
> The patch adds code to calculate and setup the SPI clock
> frequency for transfers.
> 
> Signed-off-by: Anatolij Gustschin <ag...@denx.de>
> Signed-off-by: Stefano Babic <sba...@denx.de>

Applied to u-boot-imx, thanks

Best regards,
Stefano Babic

-- 
=====================================================================
DENX Software Engineering GmbH,     MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-0 Fax: +49-8142-66989-80  Email: off...@denx.de
=====================================================================
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot

Reply via email to