On 20.09.21 01:07, Sean Anderson wrote:
Is it possible to get this in 2020.10?

Let me check, if I can find my time machine somewhere. ;)

But yes, v2021.10 should be possible. I'm just back from vacation and
will look into the new patches very soon.

Thanks,
Stefan

Meng's patch breaks boards which use this watchdog.

--Sean

On 9/11/21 3:11 PM, Sean Anderson wrote:
reset_*_bulk expects a real pointer.

Fixes: 4f7abafe1c ("driver: watchdog: reset watchdog in designware_wdt_stop() function")
Signed-off-by: Sean Anderson <sean...@gmail.com>
---

  drivers/watchdog/designware_wdt.c | 10 +++++-----
  1 file changed, 5 insertions(+), 5 deletions(-)

diff --git a/drivers/watchdog/designware_wdt.c b/drivers/watchdog/designware_wdt.c
index afed81e6c6..cfec29bd15 100644
--- a/drivers/watchdog/designware_wdt.c
+++ b/drivers/watchdog/designware_wdt.c
@@ -22,7 +22,7 @@
  struct designware_wdt_priv {
      void __iomem    *base;
      unsigned int    clk_khz;
-    struct reset_ctl_bulk *resets;
+    struct reset_ctl_bulk resets;
  };
  /*
@@ -99,11 +99,11 @@ static int designware_wdt_stop(struct udevice *dev)
          if (CONFIG_IS_ENABLED(DM_RESET)) {
          int ret;
-        ret = reset_assert_bulk(priv->resets);
+        ret = reset_assert_bulk(&priv->resets);
          if (ret)
              return ret;
-        ret = reset_deassert_bulk(priv->resets);
+        ret = reset_deassert_bulk(&priv->resets);
          if (ret)
              return ret;
      }
@@ -156,11 +156,11 @@ static int designware_wdt_probe(struct udevice *dev)
  #endif
      if (CONFIG_IS_ENABLED(DM_RESET)) {
-        ret = reset_get_bulk(dev, priv->resets);
+        ret = reset_get_bulk(dev, &priv->resets);
          if (ret)
              goto err;
-        ret = reset_deassert_bulk(priv->resets);
+        ret = reset_deassert_bulk(&priv->resets);
          if (ret)
              goto err;
      }



Viele Grüße,