wkup_vtm populates only 1 power-domain cell in it's node. But the
power-domain cell are defined as 2. Due to this the following warning
comes during build:

arch/arm/dts/k3-am654-r5-base-board.dtb: Warning (power_domains_property):
/interconnect@100000/interconnect@28380000/interconnect@42040000/
wkup_vtm@42050000:power-domains: property size (8) too small for cell size 2

Fix this by updating the power-domain cells.

Fixes: cfa6bd549c ("arm: dts: k3-am654-r5-base-board: Add VTM node")
Signed-off-by: Lokesh Vutla <lokeshvu...@ti.com>
---
 arch/arm/dts/k3-am654-r5-base-board.dts | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/arch/arm/dts/k3-am654-r5-base-board.dts 
b/arch/arm/dts/k3-am654-r5-base-board.dts
index 5c110ef9dd..5d5689d284 100644
--- a/arch/arm/dts/k3-am654-r5-base-board.dts
+++ b/arch/arm/dts/k3-am654-r5-base-board.dts
@@ -100,7 +100,7 @@
        wkup_vtm0: wkup_vtm@42050000 {
                compatible = "ti,am654-vtm", "ti,am654-avs";
                reg = <0x42050000 0x25c>;
-               power-domains = <&k3_pds 80>;
+               power-domains = <&k3_pds 80 TI_SCI_PD_EXCLUSIVE>;
                #thermal-sensor-cells = <1>;
        };
 
-- 
2.23.0