The rk3399 VD_CENTER voltage domain is not subject to dynamic voltage scaling. So the regulator reset voltage of 0.9V is used on this board. Let u-boot initialize the center voltage to 0.95V as it is done for the VD_LOGIC domain. This avoids instability and occasional linux kernel Opses on this board.
Signed-off-by: Soeren Moch <sm...@web.de> --- Cc: Kever Yang <kever.y...@rock-chips.com> Cc: u-boot@lists.denx.de --- arch/arm/dts/rk3399-rockpro64-u-boot.dtsi | 5 +++++ 1 file changed, 5 insertions(+) diff --git a/arch/arm/dts/rk3399-rockpro64-u-boot.dtsi b/arch/arm/dts/rk3399-rockpro64-u-boot.dtsi index a073ea25f5..4648513ea9 100644 --- a/arch/arm/dts/rk3399-rockpro64-u-boot.dtsi +++ b/arch/arm/dts/rk3399-rockpro64-u-boot.dtsi @@ -11,6 +11,11 @@ }; }; +&vdd_center { + regulator-min-microvolt = <950000>; + regulator-max-microvolt = <950000>; +}; + &vdd_log { regulator-init-microvolt = <950000>; }; -- 2.17.1 _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de https://lists.denx.de/listinfo/u-boot