Hi Mike, On Fri, Apr 23, 2010 at 11:08:10AM -0400, Mike Frysinger wrote: > On Friday 23 April 2010 04:43:07 Wolfgang Wegner wrote: > > However, one of the things I had to change was the dummy data sent > > out by SPI for read-only transactions. The original driver had all > > zeros, for SD/MMC all ones (0xFF) is needed. > > > > Is such a change acceptable, or is there any configuration option/flag > > I could use? > > if it isnt part of the SPI/MMC spec, use a config option named like IDLE_VAL. >
the problem exists in the (coldfire) SPI driver, not in the MMC/SD code. (For SD, the spec IMHO clearly states 0xFF for all idle transfers.) > changing the default to 0xff is OK i think. I could add CONFIG_SPI_IDLE_VAL and default it to 0x0 in the coldfire SPI driver. In case one wants to use MMC/SD with this driver, one could then add CONFIG_SPI_IDLE_VAL as 0xFF in the board to override it. (Only pitfall is that the current 0x0 is used for 8- as well as 16-bit transfers...) ok? > -mike Regards, Wolfgang _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot