On 10.12.18 11:52, Patrick Delaunay wrote:
In case of DT boot, don't read default speed and mode for SPI from
CONFIG_*, instead read from DT node.
Signed-off-by: Patrick Delaunay <patrick.delau...@st.com>
---
board/gardena/smart-gateway-mt7688/board.c | 24 ++++++++++++++++++++----
1 file changed, 20 insertions(+), 4 deletions(-)
diff --git a/board/gardena/smart-gateway-mt7688/board.c
b/board/gardena/smart-gateway-mt7688/board.c
index 6e11077..8a67e70 100644
--- a/board/gardena/smart-gateway-mt7688/board.c
+++ b/board/gardena/smart-gateway-mt7688/board.c
@@ -89,6 +89,14 @@ static void factory_data_env_config(void)
u32 crc;
int ret;
u8 *ptr;
+ /* In DM mode, defaults will be taken from DT */
+ unsigned int speed = 0;
+ unsigned int mode = 0;
+
+#ifndef CONFIG_DM_SPI_FLASH
+ speed = CONFIG_SF_DEFAULT_SPEED;
+ mode = CONFIG_SF_DEFAULT_MODE;
+#endif
CONFIG_DM_SPI_FLASH is always enabled in this board. So there should
be no need to handle the non-DM case at all.
Could you please change this patch and remove this unnecessary code?
Thanks,
Stefan
buf = malloc(FACTORY_DATA_SIZE);
if (!buf) {
@@ -101,8 +109,8 @@ static void factory_data_env_config(void)
*/
sf = spi_flash_probe(CONFIG_SF_DEFAULT_BUS,
CONFIG_SF_DEFAULT_CS,
- CONFIG_SF_DEFAULT_SPEED,
- CONFIG_SF_DEFAULT_MODE);
+ speed,
+ mode);
if (!sf) {
printf("F-Data:Unable to access SPI NOR flash\n");
goto err_free;
@@ -207,6 +215,14 @@ int do_fd_write(cmd_tbl_t *cmdtp, int flag, int argc, char
* const argv[])
struct spi_flash *sf;
u8 *buf;
int ret = CMD_RET_FAILURE;
+ /* In DM mode, defaults will be taken from DT */
+ unsigned int speed = 0;
+ unsigned int mode = 0;
+
+#ifndef CONFIG_DM_SPI_FLASH
+ speed = CONFIG_SF_DEFAULT_SPEED;
+ mode = CONFIG_SF_DEFAULT_MODE;
+#endif
buf = malloc(FACTORY_DATA_SECT_SIZE);
if (!buf) {
@@ -216,8 +232,8 @@ int do_fd_write(cmd_tbl_t *cmdtp, int flag, int argc, char
* const argv[])
sf = spi_flash_probe(CONFIG_SF_DEFAULT_BUS,
CONFIG_SF_DEFAULT_CS,
- CONFIG_SF_DEFAULT_SPEED,
- CONFIG_SF_DEFAULT_MODE);
+ speed,
+ mode);
if (!sf) {
printf("F-Data:Unable to access SPI NOR flash\n");
goto err_free;
Viele Grüße,
Stefan
--
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: s...@denx.de
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
https://lists.denx.de/listinfo/u-boot