On Mon, Oct 22, 2018 at 5:08 PM Fabio Estevam <feste...@gmail.com> wrote: > > Hi Joe, > > On Mon, Oct 22, 2018 at 6:07 PM Joe Hershberger <joe.hershber...@ni.com> > wrote: > > > > On Thu, Oct 18, 2018 at 9:15 AM Anatolij Gustschin <ag...@denx.de> wrote: > > > > > > Add compatible property and enable the FEC ipg clock when probing > > > on i.MX8X. Add specific function for reading FEC clock rate via > > > clock driver when configuring MII speed register. Allow FEC_MXC > > > selection for i.MX8. > > > > > > Signed-off-by: Anatolij Gustschin <ag...@denx.de> > > > Cc: Joe Hershberger <joe.hershber...@ni.com> > > > > Acked-by: Joe Hershberger <joe.hershber...@ni.com> > > A bit off topic, but I notice that your replies are sent two or three > times to the mailing list.
I've noticed that as well... it seems something has been screwed up on the Google servers I use to send emails to the list. I've reported the issue and have gotten no response. I'll report it again. Oddly the messages get uniquified in the archives, presumably because the message IDs are the same. Apologies, -Joe _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de https://lists.denx.de/listinfo/u-boot