On 09/08/15 09:50, Dmitry Lifshitz wrote:
> SBC-T3517 evaluation board has two Eth interfaces.
> Enable network retry of another interface if the default if failed
> or disconnected.
> 
> Add 'netretry=yes' in the default env. Setup relevant
> timeout values in the board config file.
> 
> Signed-off-by: Dmitry Lifshitz <lifsh...@compulab.co.il>

Acked-by: Igor Grinberg <grinb...@compulab.co.il>

> ---
>  include/configs/cm_t3517.h |    3 +++
>  1 files changed, 3 insertions(+), 0 deletions(-)
> 
> diff --git a/include/configs/cm_t3517.h b/include/configs/cm_t3517.h
> index a8d0b97..2d16799 100644
> --- a/include/configs/cm_t3517.h
> +++ b/include/configs/cm_t3517.h
> @@ -170,6 +170,7 @@
>       "loadaddr=0x82000000\0" \
>       "baudrate=115200\0" \
>       "console=ttyO2,115200n8\0" \
> +     "netretry=yes\0" \
>       "mpurate=auto\0" \
>       "vram=12M\0" \
>       "dvimode=1024x768MR-16@60\0" \
> @@ -275,6 +276,8 @@
>  #define CONFIG_SMC911X
>  #define CONFIG_SMC911X_32_BIT
>  #define CONFIG_SMC911X_BASE  (0x2C000000 + (16 << 20))
> +#define CONFIG_ARP_TIMEOUT           200UL
> +#define CONFIG_NET_RETRY_COUNT               5
>  #endif /* CONFIG_CMD_NET */
>  
>  /* additions for new relocation code, must be added to all boards */
> 

-- 
Regards,
Igor.
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot

Reply via email to