Dear Dimitar Dimitrov, In message <200907142209.57504.dinu...@gmail.com> you wrote: > This is my second try for Olimex SAM9-L9260/61 board support patches. > I deleted the board ethernet initialization and hopefully will add > it later in a state that can be accepted. > > Here follows the first patch. > --- > > Boards utilizing the Atmel LCD driver can now specify that the LCD clock must > be inverted by defining the macro CONFIG_ATMEL_LCD_INVCLK. > > Signed-off-by: Dimitar Dimitrov <dinu...@gmail.com> > --- > drivers/video/atmel_lcdfb.c | 3 +++ > 1 files changed, 3 insertions(+), 0 deletions(-) > > diff --git a/drivers/video/atmel_lcdfb.c b/drivers/video/atmel_lcdfb.c > index db86763..64f8e87 100644 > --- a/drivers/video/atmel_lcdfb.c > +++ b/drivers/video/atmel_lcdfb.c > @@ -112,6 +112,9 @@ void lcd_ctrl_init(void *lcdbase) > > value |= panel_info.vl_sync; > value |= (panel_info.vl_bpix << 5); > +#if defined(CONFIG_ATMEL_LCD_INVCLK) > + value |= ATMEL_LCDC_INVCLK_INVERTED; > +#endif
Please remove the "ATMEL_" part from the #define. The feature might be interesting for other processors / systems as well. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w...@denx.de Q: What do you get when you cross an ethernet with an income statement? A: A local area networth. _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot