On Thu, Jun 04, 2015 at 04:42:37PM +0530, Lokesh Vutla wrote: > In addition to the regular mux configuration, certain pins of DRA7 > require to have "manual mode" also programmed, when predefined > delay characteristics cannot be used for the interface. > > struct iodelay_cfg_entry is introduced for populating > manual mode IO timings. > For configuring manual mode, along with the normal pad > configuration do the following steps: > - Select MODESELECT field of each assocaited PAD. > CTRL_CORE_PAD_XXX[8]:MODESELECT = 1(Enable MANUAL_MODE macro along with mux) > - Populate A_DELAY, G_DELAY values that are specified in DATA MANUAL. > And pass the offset of the CFG_XXX register in iodelay_cfg_entry. > > Signed-off-by: Lokesh Vutla <lokeshvu...@ti.com> > Signed-off-by: Nishanth Menon <n...@ti.com>
Applied to u-boot/master, thanks! -- Tom
signature.asc
Description: Digital signature
_______________________________________________ U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot