Or:

Ambisonic spherical convention is left-oriented. 
The +ve X axis showing into the 0 degree direction for both, azimuth and 
elevation.  
The azimuth increases counterclockwise towards the +ve Y axis.  
Elevation is +ve above the XY plane, and - ve for below.  

I got this wrong when I first used the ADT, but Aaron Heller (thanks), spotted 
it.
Dual band decoding with parametric up-mixing (Harpex), is definitely 
recommended for first order on a 3rd order rig.

You could also do a decode to less speakers, or to binaural to check?

Best

Steve
> On 6 Jul 2017, at 00:39, Steven Boardman <boardroomout...@gmail.com> wrote:
> 
> Check what convention the ADT uses for speaker co-ordinates. It may be that 
> you have some of your + or -  the wrong way round, or assigned to the 
> incorrect axis.  
> For Ambisonics convention, 
>  X is front and back, Y is left and right, Z is up and down. 
> It is a 90 degree rotation from graphics convention (+x right, +y forward, +z 
> up). 
> This would obviously make a big difference to the decode, and one that i have 
> been stumped by myself many times.. 
> 
> Steve 

_______________________________________________
Sursound mailing list
Sursound@music.vt.edu
https://mail.music.vt.edu/mailman/listinfo/sursound - unsubscribe here, edit 
account or options, view archives and so on.

Reply via email to