smartctl 6.2 2013-07-26 r3841 [i686-w64-mingw32-win8(64)] (sf-6.2-1)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: Hitachi HDS721050CLA662
Serial Number: JP1572JE27EBBK
LU WWN Device Id: 5 000cca 397df8fc8
Firmware Version: JP2OA41A
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Mar 11 11:02:05 2014 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting
command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4978) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 83) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 096 016 - 0
2 Throughput_Performance POS--K 136 100 054 - 94
3 Spin_Up_Time PO---K 119 100 024 - 190 (Average 195)
4 Start_Stop_Count -O---K 100 100 000 - 86
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate POSR-K 100 100 067 - 0
8 Seek_Time_Performance P-S--K 140 100 020 - 30
9 Power_On_Hours -O--CK 098 098 000 - 20642
10 Spin_Retry_Count PO--CK 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 85
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
185 Unknown_Attribute -O--CK 100 100 000 - 65535
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 098 000 - 4295622821
189 High_Fly_Writes -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 067 058 000 - 33 (Min/Max 31/40)
192 Power-Off_Retract_Count -O--CK 100 100 000 - 109
193 Load_Cycle_Count -O--CK 100 100 000 - 109
194 Temperature_Celsius -O---- 181 150 000 - 33 (Min/Max 21/42)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL R/O 7 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters
0x20 GPL R/O 1 Streaming performance log [OBS-8]
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 0 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Extended offline Interrupted (host reset) 90% 1 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
SCT Support Level: 1
Device State: SMART Off-line Data Collection executing
in background (4)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 31/40 Celsius
Lifetime Min/Max Temperature: 21/42 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (64)
Index Estimated Time Temperature Celsius
65 2014-03-11 08:55 32 *************
... ..( 2 skipped). .. *************
68 2014-03-11 08:58 32 *************
69 2014-03-11 08:59 33 **************
... ..( 60 skipped). .. **************
2 2014-03-11 10:00 33 **************
3 2014-03-11 10:01 34 ***************
4 2014-03-11 10:02 33 **************
5 2014-03-11 10:03 33 **************
6 2014-03-11 10:04 34 ***************
... ..( 17 skipped). .. ***************
24 2014-03-11 10:22 34 ***************
25 2014-03-11 10:23 33 **************
... ..( 2 skipped). .. **************
28 2014-03-11 10:26 33 **************
29 2014-03-11 10:27 34 ***************
30 2014-03-11 10:28 33 **************
... ..( 33 skipped). .. **************
64 2014-03-11 11:02 33 **************
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
Write: 85 (8.5 seconds)
Device Statistics (GP Log 0x04)
Page Offset Size Value Description
1 ===== = = == General Statistics (rev 1) ==
1 0x008 4 85 Lifetime Power-On Resets
1 0x010 4 20642 Power-on Hours
1 0x018 6 24411179514 Logical Sectors Written
1 0x020 6 447198402 Number of Write Commands
1 0x028 6 171339471486 Logical Sectors Read
1 0x030 6 514121710 Number of Read Commands
3 ===== = = == Rotating Media Statistics (rev 1) ==
3 0x008 4 20638 Spindle Motor Power-on Hours
3 0x010 4 20638 Head Flying Hours
3 0x018 4 109 Head Load Events
3 0x020 4 0 Number of Reallocated Logical Sectors
3 0x028 4 2 Read Recovery Attempts
3 0x030 4 2 Number of Mechanical Start Failures
4 ===== = = == General Errors Statistics (rev 1) ==
4 0x008 4 0 Number of Reported Uncorrectable Errors
4 0x010 4 165 Resets Between Cmd Acceptance and Completion
5 ===== = = == Temperature Statistics (rev 1) ==
5 0x008 1 33 Current Temperature
5 0x010 1 33~ Average Short Term Temperature
5 0x018 1 33~ Average Long Term Temperature
5 0x020 1 42 Highest Temperature
5 0x028 1 21 Lowest Temperature
5 0x030 1 37~ Highest Average Short Term Temperature
5 0x038 1 0~ Lowest Average Short Term Temperature
5 0x040 1 33~ Highest Average Long Term Temperature
5 0x048 1 0~ Lowest Average Long Term Temperature
5 0x050 4 0 Time in Over-Temperature
5 0x058 1 60 Specified Maximum Operating Temperature
5 0x060 4 0 Time in Under-Temperature
5 0x068 1 0 Specified Minimum Operating Temperature
6 ===== = = == Transport Statistics (rev 1) ==
6 0x008 4 427 Number of Hardware Resets
6 0x010 4 149 Number of ASR Events
6 0x018 4 0 Number of Interface CRC Errors
|_ ~ normalized value
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
------------------------------------------------------------------------------
Learn Graph Databases - Download FREE O'Reilly Book
"Graph Databases" is the definitive new guide to graph databases and their
applications. Written by three acclaimed leaders in the field,
this first edition is now available. Download your free book today!
http://p.sf.net/sfu/13534_NeoTech
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database