smartctl 6.2 2013-07-26 r3841 [i686-w64-mingw32-win7(64)-sp1] (sf-6.2-1)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: VisionTek GoDrive 480GB
Serial Number: VT1308A00001592
LU WWN Device Id: 0 000120 000000000
Firmware Version: 506ABBF0
User Capacity: 480,103,981,056 bytes [480 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Fri Jan 17 16:41:26 2014 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Disabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Unexpected SCT status 0x0010 (action_code=4, function_code=2)
Wt Cache Reorder: N/A
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0021) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 099 099 050 - 2633144
5 Reallocated_Sector_Ct PO--CK 100 100 003 - 0
9 Power_On_Hours -O--CK 097 097 000 - 3408 (10 42 0)
12 Power_Cycle_Count -O--CK 100 100 000 - 124
171 Unknown_Attribute -O--CK 000 000 000 - 0
172 Unknown_Attribute -O--CK 000 000 000 - 0
174 Unknown_Attribute ----CK 000 000 000 - 43
177 Wear_Leveling_Count ------ 000 000 000 - 0
181 Program_Fail_Cnt_Total -O--CK 000 000 000 - 0
182 Erase_Fail_Count_Total -O--CK 000 000 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel ------ 128 129 000 - 128 (0 127 0 129 0)
194 Temperature_Celsius -O---K 128 129 000 - 128 (0 127 0 129 0)
195 Hardware_ECC_Recovered --SRC- 120 120 000 - 2633144
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unknown_SSD_Attribute --SRC- 120 120 000 - 2633144
204 Soft_ECC_Correction --SRC- 120 120 000 - 2633144
230 Unknown_SSD_Attribute PO--C- 100 100 000 - 100
231 Temperature_Celsius PO--C- 100 100 010 - 0
233 Media_Wearout_Indicator ------ 000 000 000 - 2018
234 Unknown_Attribute -O--CK 000 000 000 - 1457
241 Total_LBAs_Written -O--CK 000 000 000 - 1457
242 Total_LBAs_Read -O--CK 000 000 000 - 4775
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 0
SMART Log Directory Version 0
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been
run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: ? Celsius
Power Cycle Min/Max Temperature: 127/-127 Celsius
Lifetime Min/Max Temperature: 0/ 0 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 0 (Unknown, should be 2)
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/ 0 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 0 (474)
Temperature History is empty
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x0002 2 0 R_ERR response for data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
------------------------------------------------------------------------------
CenturyLink Cloud: The Leader in Enterprise Cloud Services.
Learn Why More Businesses Are Choosing CenturyLink Cloud For
Critical Workloads, Development Environments & Everything In Between.
Get a Quote or Start a Free Trial Today.
http://pubads.g.doubleclick.net/gampad/clk?id=119420431&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database