Hello.

  smartctl -x output is in attachment.

  Please note that sector sizes of '512 bytes logical, 4096 bytes physical' 
because drive is
  attached to HBA controller as JBOD drive and in this mode only 512 bytes 
sector is available.

Best regards,
    beelzebubbie.l...@gmail.com 
smartctl 5.42 2011-10-20 r3458 [x86_64-linux-3.8.13-gentoo-Jun13] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     Hitachi HTS727550A9E364
Serial Number:    J3360081GM1H9C
LU WWN Device Id: 5 000cca 689c8a8a8
Firmware Version: JF3OA0E0
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 6
Local Time is:    Sat Jun 29 19:33:57 2013 ALMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (  39) The self-test routine was interrupted
                                        by the host with a hard or soft reset.
Total time to complete Offline 
data collection:                (   45) seconds.
Offline data collection
capabilities:                    (0x51) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 113) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR-K   100   100   062    -    0
  2 Throughput_Performance  P-S--K   100   100   040    -    0
  3 Spin_Up_Time            PO---K   183   100   033    -    2
  4 Start_Stop_Count        -O--CK   100   100   000    -    120
  5 Reallocated_Sector_Ct   PO--CK   100   100   005    -    0
  7 Seek_Error_Rate         POSR-K   100   100   067    -    0
  8 Seek_Time_Performance   P-S--K   100   100   040    -    0
  9 Power_On_Hours          -O--CK   100   100   000    -    187
 10 Spin_Retry_Count        PO--CK   100   100   060    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    119
183 Runtime_Bad_Block       -O--CK   100   100   000    -    0
184 End-to-End_Error        PO--CK   100   100   097    -    0
187 Reported_Uncorrect      -O--CK   100   100   000    -    12884967424
188 Command_Timeout         -O--CK   100   100   000    -    0
190 Airflow_Temperature_Cel -O---K   081   053   045    -    19 (Min/Max 15/23)
191 G-Sense_Error_Rate      -O--CK   100   100   000    -    46
192 Power-Off_Retract_Count -O--CK   100   100   000    -    1441814
193 Load_Cycle_Count        -O--CK   100   100   000    -    4647
196 Reallocated_Event_Count -O--CK   100   100   000    -    0
197 Current_Pending_Sector  -O--CK   100   100   000    -    0
198 Offline_Uncorrectable   ----CK   100   100   000    -    0
199 UDMA_CRC_Error_Count    -OS-CK   100   100   000    -    0
223 Load_Retry_Count        -O-R-K   100   100   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not 
supported
Read GP Log Directory failed.

SMART Log Directory Version 1 [multi-sector log support]
SMART Log at address 0x00 has    1 sectors [Log Directory]
SMART Log at address 0x01 has    1 sectors [Summary SMART error log]
SMART Log at address 0x02 has    1 sectors [Comprehensive SMART error log]
SMART Log at address 0x06 has    1 sectors [SMART self-test log]
SMART Log at address 0x09 has    1 sectors [Selective self-test log]
SMART Log at address 0x80 has   16 sectors [Host vendor specific log]
SMART Log at address 0x81 has   16 sectors [Host vendor specific log]
SMART Log at address 0x82 has   16 sectors [Host vendor specific log]
SMART Log at address 0x83 has   16 sectors [Host vendor specific log]
SMART Log at address 0x84 has   16 sectors [Host vendor specific log]
SMART Log at address 0x85 has   16 sectors [Host vendor specific log]
SMART Log at address 0x86 has   16 sectors [Host vendor specific log]
SMART Log at address 0x87 has   16 sectors [Host vendor specific log]
SMART Log at address 0x88 has   16 sectors [Host vendor specific log]
SMART Log at address 0x89 has   16 sectors [Host vendor specific log]
SMART Log at address 0x8a has   16 sectors [Host vendor specific log]
SMART Log at address 0x8b has   16 sectors [Host vendor specific log]
SMART Log at address 0x8c has   16 sectors [Host vendor specific log]
SMART Log at address 0x8d has   16 sectors [Host vendor specific log]
SMART Log at address 0x8e has   16 sectors [Host vendor specific log]
SMART Log at address 0x8f has   16 sectors [Host vendor specific log]
SMART Log at address 0x90 has   16 sectors [Host vendor specific log]
SMART Log at address 0x91 has   16 sectors [Host vendor specific log]
SMART Log at address 0x92 has   16 sectors [Host vendor specific log]
SMART Log at address 0x93 has   16 sectors [Host vendor specific log]
SMART Log at address 0x94 has   16 sectors [Host vendor specific log]
SMART Log at address 0x95 has   16 sectors [Host vendor specific log]
SMART Log at address 0x96 has   16 sectors [Host vendor specific log]
SMART Log at address 0x97 has   16 sectors [Host vendor specific log]
SMART Log at address 0x98 has   16 sectors [Host vendor specific log]
SMART Log at address 0x99 has   16 sectors [Host vendor specific log]
SMART Log at address 0x9a has   16 sectors [Host vendor specific log]
SMART Log at address 0x9b has   16 sectors [Host vendor specific log]
SMART Log at address 0x9c has   16 sectors [Host vendor specific log]
SMART Log at address 0x9d has   16 sectors [Host vendor specific log]
SMART Log at address 0x9e has   16 sectors [Host vendor specific log]
SMART Log at address 0x9f has   16 sectors [Host vendor specific log]
SMART Log at address 0xe0 has    1 sectors [SCT Command/Status]
SMART Log at address 0xe1 has    1 sectors [SCT Data Transfer]

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged

SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Interrupted (host reset)      70%       187         -
# 2  Short offline       Completed without error       00%         2         -
# 3  Short offline       Completed without error       00%         1         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

Error Write SCT Data Table command failed: Operation not permitted
Error Write SCT (Get) Error Recovery Control Command failed: Operation not 
permitted
Warning: device does not support SCT (Get) Error Recovery Control command

SATA Phy Event Counters (GP Log 0x11) not supported
------------------------------------------------------------------------------
This SF.net email is sponsored by Windows:

Build for Windows Store.

http://p.sf.net/sfu/windows-dev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to