64GByte, Firmware Version: AXM09B1Q, smartctl 5.41 2011-06-04 r3354 Output after "smartctl --test=long /dev/sda" attached.
Output is significantly different from the one reported at: http://sourceforge.net/mailarchive/forum.php?thread_name=201101162245.38281.ville.skytta%40iki.fi&forum_name=smartmontools-database There's an Unknown_Attribute 235 Greetings, Frieder
smartctl 5.41 2011-06-04 r3354 [x86_64-linux-2.6.39-30-desktop] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: SAMSUNG 470 Series SSD Serial Number: S0SUNEAB400720 Firmware Version: AXM09B1Q User Capacity: 64.023.257.088 bytes [64,0 GB] Sector Size: 512 bytes logical/physical Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 1 Local Time is: Sun Jun 5 23:52:40 2011 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 420) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 7) minutes. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 9 Power_On_Hours 0x0032 099 099 --- Old_age Always - 2 12 Power_Cycle_Count 0x0032 099 099 --- Old_age Always - 6 177 Wear_Leveling_Count 0x0013 099 099 --- Pre-fail Always - 1 178 Used_Rsvd_Blk_Cnt_Chip 0x0013 077 077 --- Pre-fail Always - 234 190 Airflow_Temperature_Cel 0x0022 067 065 --- Old_age Always - 33 235 Unknown_Attribute 0x0012 099 099 --- Old_age Always - 3 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 2 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------ Simplify data backup and recovery for your virtual environment with vRanger. Installation's a snap, and flexible recovery options mean your data is safe, secure and there when you need it. Discover what all the cheering's about. Get your free trial download today. http://p.sf.net/sfu/quest-dev2dev2
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database