Apparently this drive does not support the short selftest (-t short) - as with 
the Vertex2 PRO it claims that the test is started, but after waiting hours the 
completion stays at 90% remaining.

smartctl 5.40 2010-10-16 r3189 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     OCZ-ONYX
Serial Number:    G52XH0KYRFS1742FTV45
Firmware Version: 1.6
User Capacity:    32.017.047.552 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Fri Nov 19 14:17:11 2010 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 249) Self-test routine in progress...
                                        90% of test remaining.
Total time to complete Offline 
data collection:                 (   0) seconds.
Offline data collection
capabilities:                    (0x1d) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Abort Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x00) Error logging NOT supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   0) minutes.
Extended self-test routine
recommended polling time:        (   0) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0000   006   000   000    Old_age   Offline      
-       0
  9 Power_On_Hours          0x0000   176   000   000    Old_age   Offline      
-       0
 12 Power_Cycle_Count       0x0000   017   000   000    Old_age   Offline      
-       0
184 End-to-End_Error        0x0000   014   000   000    Old_age   Offline      
-       0
195 Hardware_ECC_Recovered  0x0000   000   000   000    Old_age   Offline      
-       0
196 Reallocated_Event_Count 0x0000   000   000   000    Old_age   Offline      
-       0
197 Current_Pending_Sector  0x0000   000   000   000    Old_age   Offline      
-       0
198 Offline_Uncorrectable   0x0000   166   111   000    Old_age   Offline      
-       1064
199 UDMA_CRC_Error_Count    0x0000   245   055   000    Old_age   Offline      
-       1610
200 Multi_Zone_Error_Rate   0x0000   159   057   000    Old_age   Offline      
-       12
201 Soft_Read_Error_Rate    0x0000   055   067   000    Old_age   Offline      
-       21
202 Data_Address_Mark_Errs  0x0000   097   015   000    Old_age   Offline      
-       1
203 Run_Out_Cancel          0x0000   088   008   000    Old_age   Offline      
-       1
204 Soft_ECC_Correction     0x0000   000   000   000    Old_age   Offline      
-       0
205 Thermal_Asperity_Rate   0x0000   136   019   000    Old_age   Offline      
-       0
206 Flying_Height           0x0000   001   000   000    Old_age   Offline      
-       0
207 Spin_High_Current       0x0000   151   002   000    Old_age   Offline      
-       0
208 Spin_Buzz               0x0000   096   000   000    Old_age   Offline      
-       0
209 Offline_Seek_Performnce 0x0000   099   000   000    Old_age   Offline      
-       0
211 Unknown_Attribute       0x0000   000   000   000    Old_age   Offline      
-       0
212 Unknown_Attribute       0x0000   000   000   000    Old_age   Offline      
-       0
213 Unknown_Attribute       0x0000   000   000   000    Old_age   Offline      
-       0

Warning: device does not support Error Logging
Warning! SMART ATA Error Log Structure error: invalid SMART checksum.
SMART Error Log Version: 1
No Errors Logged

Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


Device does not support Selective Self Tests/Logging
------------------------------------------------------------------------------
Beautiful is writing same markup. Internet Explorer 9 supports
standards for HTML5, CSS3, SVG 1.1,  ECMAScript5, and DOM L2 & L3.
Spend less time writing and  rewriting code and more time creating great
experiences on the web. Be a part of the beta today
http://p.sf.net/sfu/msIE9-sfdev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to