The OCZ Vertex 2 PRO in our system is not yet (as of 5.40) in the Smartmontools database.
Below is a 'smartctl -a' dump. If you hack Smartmon to 'think' this drive is a regular 'Vertex 2' (not a Pro) some attributes appear OK, but others (such as the 'Supercapacitor' status that appears then) still show as 'FAILING NOW'. I did try running a short offline test before dumping the stats (as the site suggests) - this claimed to start the test, but nothing shows in the drive log - so it might not be supported / have actually worked. The drive is one of 2 in the system, and is brand new - it's had a minimal amount of data written to it (an O/S install, plus a few tests). If you need any further info / stuff testing - please let me know, -Karl smartctl -a output: " smartctl 5.40 2010-10-16 r3189 [FreeBSD 8.1-RELEASE amd64] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: OCZ VERTEX2-PRO Serial Number: f1b060006 Firmware Version: 1.10 User Capacity: 50,020,540,416 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 6 Local Time is: Tue Nov 16 08:46:06 2010 GMT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x7f) SMART execute Offline immediate. Auto Offline data collection on/off support. Abort Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 48) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 115 100 050 Pre-fail Always - 108049068 5 Reallocated_Sector_Ct 0x0033 099 099 003 Pre-fail Always - 352 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 81149112090783 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 24 13 Read_Soft_Error_Rate 0x0000 059 058 000 Old_age Offline - 55267747213996 100 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 128 170 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 17161 171 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 0 172 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 0 174 Unknown_Attribute 0x0030 000 000 000 Old_age Offline - 22 177 Wear_Leveling_Count 0x0000 000 000 --- Old_age Offline - 0 181 Program_Fail_Cnt_Total 0x0000 000 000 000 Old_age Offline - 0 182 Erase_Fail_Count_Total 0x0000 000 000 000 Old_age Offline - 0 184 End-to-End_Error 0x0032 100 100 090 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 194 Temperature_Celsius 0x0022 013 017 000 Old_age Always - 13 (Min/Max 0/17) 195 Hardware_ECC_Recovered 0x001c 115 100 000 Old_age Offline - 108049068 196 Reallocated_Event_Count 0x0033 100 100 003 Pre-fail Always - 0 198 Offline_Uncorrectable 0x0010 115 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x0000 115 100 000 Old_age Offline - 108049068 204 Soft_ECC_Correction 0x0000 115 100 000 Old_age Offline - 108049068 230 Head_Amplitude 0x0013 100 100 000 Pre-fail Always - 100 231 Temperature_Celsius 0x0013 098 098 010 Pre-fail Always - 1 232 Available_Reservd_Space 0x0000 000 000 010 Old_age Offline FAILING_NOW 16 233 Media_Wearout_Indicator 0x0000 000 000 000 Old_age Offline - 128 234 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 256 235 Unknown_Attribute 0x0033 000 000 001 Pre-fail Always FAILING_NOW 0 241 Total_LBAs_Written 0x0032 000 000 000 Old_age Always - 256 242 Total_LBAs_Read 0x0032 000 000 000 Old_age Always - 192 Error SMART Error Log Read failed: Input/output error Smartctl: SMART Error Log Read Failed Error SMART Error Self-Test Log Read failed: Input/output error Smartctl: SMART Self Test Log Read Failed SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. " ------------------------------------------------------------------------------ Beautiful is writing same markup. Internet Explorer 9 supports standards for HTML5, CSS3, SVG 1.1, ECMAScript5, and DOM L2 & L3. Spend less time writing and rewriting code and more time creating great experiences on the web. Be a part of the beta today http://p.sf.net/sfu/msIE9-sfdev2dev _______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database