Hi Damjan,
I want separate email-thread for the OCTEONTx mempool ops.
> Regarding the octeon tx mempool, no idea what it is,
OCTEONTx mempool ops uses hardware mempool allocator instead of DPDK
software mempool. This is not enabled by default in DPDK but once
enabled all buffers are managed by
Hi,
Any help here would be appreciable.
Please help with configurations.
Thanks,
Saurabh Jain
Folks,
The CSIT-VPP Test Report for VPP 18.01.2 release is now available. I
have updated the Documents section of the VPP main wiki page to provide
a links to the associated CSIT-VPP Test Reports for each VPP release:
https://wiki.fd.io/view/VPP#Documents
Many thanks to the CSIT Team for def
Xlangyun,
VAT (vpp api test) is currently used in CSIT to configure VPP during
Functional and Performance testing. There have been proposals to
replace VAT in the CSIT test framework with the Python VAPI interface,
but that has not been implemented yet.
You can search the CSIT Wiki and Docu
Steven, Damjan, Nitin,
Let me clarify so there is no confusion, since you are assisting me to
get this working I will make sure we are all on same page. I believe
OcteonTx is related to Cavium/ARM and I am not using it.
DPDK/testpmd (vhost-virtio) works with both 2MB and 1GB hugepages. For
2MB I
Hi Ravi,
Sorry for diluting your topic. From your stack trace and show interface output
I thought you are using OCTEONTx.
Regards,
Nitin
> On 06-Jun-2018, at 22:10, Ravi Kerur wrote:
>
> Steven, Damjan, Nitin,
>
> Let me clarify so there is no confusion, since you are assisting me to
> get
Damjan, Steven,
I will get back to the system on which VPP is crashing and get more
info on it later.
For now, I got hold of another system (same 16.04 x86_64) and I tried
with the same configuration
VPP vhost-user on host
VPP virtio-user on a container
This time VPP didn't crash. Ping doesn't
Patch is in gerrit[1] but it keeps 18.02 as default. We will bump to 18.05 in
the separate one.
This exercise resulted in one bug found in dpdk 18.05. Patch[2] sent upstream...
Due to this bug, if VPP is linked against non-patched DPDK 18.05, XL710 VF
driver will not work.
VPP will skip device
Ravi,
I supposed you already checked the obvious that the vhost connection is
established and shared memory has at least 1 region in show vhost. For traffic
issue, use show error to see why packets are dropping. trace add
vhost-user-input and show trace to see if vhost is getting the packet.
S
Hi Steven
Shared memory is setup correctly. I am seeing following errors. System
on which there is no crash it doesn't support 1G hugepages. So I have
to use 2M hugepages with following config for VPP.
(1) host
vpp# show error
CountNode Reason
vpp# show e
10 matches
Mail list logo