Hey Jason,
In regards to your original post, I wonder if the issue is due to the split
stream block. Perhaps it has a bubble state and cannot keep up at full
rate. Have you tried moving the Keep One in N before the split stream?
Jonathon
On Tue, Sep 25, 2018 at 10:07 PM Jason Matusiak via USRP-u
OK, now I am really confused.
Part of my math issue seems to be that I set the "sample rate" in the RFNoC
radio to be my sample_rate because I knew I could ignore due to the lack of DDC
(it would then be set to the master clock rate).
When I run my flowgraph, I see that the master clock rate