On 02/12/2019 05:55 AM, Maria Jesus Cañavate Sanchez via USRP-users wrote:
Hi there!
I am having problems when connecting the USRP X310 to my PC via a
switch (I am doing this as I would like to connect several USRPs
simultaneously). The connection between the PC and the USRP via direct
Ethern
Hi Leandro,
Thank you very much for your answer!
I think that might not be the problem as I was using just one USRP (I
was basically checking if it was working with the switch before
connecting more of them).
Best regards,
Maria Jesus
On 12/02/2019 12:13, Leandro Echevarría wrote:
Hey Mar
Hey Maria,
If I'm not wrong, USRPs have default static IP addresses, which are
specific to the FPGA image you've loaded onto them. Perhaps if you're using
more than one in the same network domain there's being a collision and you
need to change one of the board's IP default IP addresses first? Jus
Hi Xavier,
Thank you very much for your answer!
I was just using the command uhd_find_devices from the terminal and the
PC did not detect anything. Sending a ping did not work either. When I
did the same by connecting just the PC without the switch, everything
worked properly.
Do you think
Hi there!
I am having problems when connecting the USRP X310 to my PC via a switch
(I am doing this as I would like to connect several USRPs
simultaneously). The connection between the PC and the USRP via direct
Ethernet connection works perfectly but not when I connect a switch in
between. I