[USRP-users] Re: ADC saturation problem in USRP X310

2024-10-18 Thread Patrice PAJUSCO
Dear Marcus, thank you for your answer. Just to clarify the problem a little better. We use a UBX160 daughter card. To have optimal SNR, an automatic gain control has been implemented based on the max IQ value. The sample rate is 30.72 for LTE decoding. Unfortunately, high power exists outsi

[USRP-users] Re: ADC saturation problem in USRP X310

2024-10-18 Thread Patrice PAJUSCO
why it is important for us to have a good quality of sampling De: "Marcus D. Leech" À: "Brian Padalino" , "Patrice PAJUSCO" Cc: "usrp-users" Envoyé: Vendredi 18 Octobre 2024 18:13:57 Objet: Re: [USRP-users] Re: ADC saturation problem in USRP X3

[USRP-users] Re: How to have 10MHz on REF OUT with a master clock of 184.32 MHz

2023-08-04 Thread patrice . pajusco
Dear Brian, Thank you for the different possible options. Patrice ___ USRP-users mailing list -- usrp-users@lists.ettus.com To unsubscribe send an email to usrp-users-le...@lists.ettus.com

[USRP-users] Re: How to have 10MHz on REF OUT with a master clock of 184.32 MHz

2023-08-04 Thread patrice . pajusco
Dear all, I plan to use 2 USPRs to analyze LTE signal. One will use a GPSDO to have a good clock and time reference. To have synchronization between them, the second one will be set on external synchronization (ref out -> ref in, for 10 MHz and PPS). A Master clock of 184 is recommended for LTE