Hello James,
Unfortunately, the Replay block doesn't currently support timed commands,
so the behavior you saw is expected. This is something that we have
discussed as a future improvement. In the mean time, I think that your
Verilog modifications might be the right approach.
Thanks,
Wade
On Tu
Hi all,
I'm getting the following LookupError after making/installing
UHD_003.010.003 and building/writing the bitstream for the X310_HG project:
-
linux; GNU C++ version 7.3.0; Boost_106501; UHD_003.010.003.HEAD-0-gef157678
-- X300 initialization sequence...
-- De
Hi,
Is there any method can control the timing for the RFNOC Replay Block in X310?
I tried adding time spec but the transmitter failed to start. In fact, as long
as I set "stream_cmd.stream_now = false;" then, the transmitter will not turn
on unless set it back to true and power restart the X310
On 02/05/2019 06:44 AM, Lucas Val Terrón via USRP-users wrote:
Hello all,
My goal is to launch two independent applications from the same SBC.
Each of them needs to use exclusively one USRP B200mini. The
incovenience is that once I launch one app, e.g. linked to
USRP_B200mini_1, the other one
Hello all,
My goal is to launch two independent applications from the same SBC. Each
of them needs to use exclusively one USRP B200mini. The incovenience is
that once I launch one app, e.g. linked to USRP_B200mini_1, the other one
(USRP_B200mini_2) dissapears. I check this using usrp_find_devices