Hi
First, Could you please try this problem still there if use flink 1.10 or
1.11?
It seems strange, from the error message, here is an error when trying to
convert a non-Window state(VoidNameSpace) to a Window State (serializer is
the serializer of Window state, but the state is non-Window state
Hi SmileSmile
As the OOM problem, maybe you can try to get a memory dump before OOM,
after you get the memory dump, you can know who consumes more memory as
expected.
Best,
Congxian
Yun Tang 于2020年7月3日周五 下午3:04写道:
> Hi
>
> If you do not enable checkpoint and have you ever restored checkpoint
Hi Benchao
The capacity is 100
Parallelism is 8
Rpc req is 20ms
Thanks
On Sun, 5 Jul 2020, 6:16 Benchao Li, wrote:
> Hi Mark,
>
> Could you give more details about your Flink job?
> - the capacity of AsyncDataStream
> - the parallelism of AsyncDataStream operator
> - the time of per blocked r
As I already mentioned,
> I would suggest to look into the jobmanager logs and gc logs, see if
> there's any problem that prevent the process from handling the rpc messages
> timely.
>
The Akka ask timeout does not seem to be the root problem to me.
Thank you~
Xintong Song
On Sat, Jul 4, 202
Hi, Kim
The reason your attempts (2) and (3) failed is that the json format does not
support convert a BIGINT to TIMESTAMP, you can first define the BIGINT field
and then use a computed column to extract TIMESTAMP field, you can also define
the time attribute on TIMESTAMP filed for using time-b
In this sequence of (checkpoint x, savepoint y, checkpoint x+1), does
checkpoint x+1 build the incremental diff based on checkpoint x or
savepoint y?
Thanks,
Steven
In a slightly different variation of sequence (checkpoint x, savepoint y,
redeploy/restart job from savepoint y, checkpoint x+1), checkpoint x+1
builds the incremental diff on savepoint y, right?
On Sun, Jul 5, 2020 at 8:08 PM Steven Wu wrote:
>
> In this sequence of (checkpoint x, savepoint y,
Hi Kostas,
I'm confused about the implementation of the temporary workaround. Would it
be possible to get a little more detail?
> you could simply not stop the job after the whole input is processed
How does one determine when the job has processed the whole input?
> then wait until the outp
Hi, everyone!
When i use flink1.10 to define table, and i want to define the json array
as the string type. But the query resutl is null when i execute the program.
The detail code as follow:
package com.flink;
import
org.apache.flink.streaming.api.environment.StreamExecutionEnvironment;
import
Hi Leonard,
Wow, that's great! It works like a charm.
I've never considered this approach at all.
Thanks a lot.
Best,
Dongwon
On Mon, Jul 6, 2020 at 11:26 AM Leonard Xu wrote:
> Hi, Kim
>
> The reason your attempts (2) and (3) failed is that the json format does
> not support convert a BIGINT
10 matches