Re: [Smartmontools-database] smartctl-output

2010-08-23 Thread Christian Franke
Wolf wrote: > Thanks for the update. > > Vendor Specific SMART Attributes are now shown ok, but there are still > some errors: > > Error SMART Error Log Read failed: Input/output error > I'm not sure if it's related to smartctl or drive itself. > It is probably related to smartctl, see http://so

Re: [Smartmontools-database] smartctl-output

2010-08-22 Thread Roman
Hi, Thanks for the update. Vendor Specific SMART Attributes are now shown ok, but there are still some errors: > Error SMART Error Log Read failed: Input/output error I'm not sure if it's related to smartctl or drive itself. Logs are attached. -- Wolf On 2010-08-20 08:34, Christian Franke

Re: [Smartmontools-database] smartctl-output

2010-08-19 Thread Christian Franke
Christian Franke wrote: > Wolf wrote: > >> Hi, >> >> >> In attachment there is result of smartctl with -r ioctl,2 >> >> Hope this help. >> >> > [...] > Other features (e.g. new format of Power_On_Hours) will be added soon. > Done in r3134. Please test smartctl from current SVN. It s

Re: [Smartmontools-database] smartctl-output

2010-08-17 Thread Christian Franke
Wolf wrote: > Hi, > > > In attachment there is result of smartctl with -r ioctl,2 > > Hope this help. > Thanks. > 177 Wear_Leveling_Count 0x 000 000 ---Old_age Offline > - 0 > 177 Wear_Leveling_Count<== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS > TWO > 181

Re: [Smartmontools-database] smartctl-output

2010-08-16 Thread Roman
Hi, Christian Franke wrote: > In the OCZ forum "GrayWolf" thankfully did so > http://www.ocztechnologyforum.com/forum/showthread.php?76514-Vertex-2-SMART-says-drive-is-failing&p=544788&viewfull=1#post544788 > and got: > > --8< > smartctl 5.39.1 2010-

Re: [Smartmontools-database] smartctl-output

2010-08-15 Thread Christian Franke
Hi Frieder, > Am 30.07.2010 18:43, schrieb Christian Franke: > >> Attached is a suggested database entry, please test (use -B option or >> copy file to /etc). >> >> > In the OCZ forum "GrayWolf" thankfully did so > > http://www.ocztechnologyforum.com/forum/showthread.php?76514-Vertex-2

Re: [Smartmontools-database] smartctl-output

2010-08-15 Thread Frieder Ferlemann
Hi Christian, Am 30.07.2010 18:43, schrieb Christian Franke: > > Attached is a suggested database entry, please test (use -B option or > copy file to /etc). > In the OCZ forum "GrayWolf" thankfully did so http://www.ocztechnologyforum.com/forum/showthread.php?76514-Vertex-2-SMART-says-drive-i

Re: [Smartmontools-database] smartctl-output

2010-07-30 Thread Christian Franke
Frieder Ferlemann wrote: Hi, Am 15.07.2010 12:41, schrieb Manfred Schwarb: play an important role, of course. So we may need to change these settings as soon as we have some information about them. Hi, they have been published here yesterday: http://www.ocztechnologyforum.com/forum/

Re: [Smartmontools-database] smartctl-output

2010-07-29 Thread Frieder Ferlemann
Hi, Am 15.07.2010 12:41, schrieb Manfred Schwarb: > play an important role, of course. So we may need to change these > settings as soon as we have some information about them. Hi, they have been published here yesterday: http://www.ocztechnologyforum.com/forum/showthread.php?75786-SMART-Attribu

Re: [Smartmontools-database] smartctl-output

2010-07-15 Thread Manfred Schwarb
> Hi Manfred, > > Am 14.07.2010 23:23, schrieb Manfred Schwarb: > > Am 13.07.2010 12:05, schrieb Frieder Ferlemann: > >> I don't believe the OCZ-AGILITY2 is supported with the r3123 change:) > > For me it works, why do you believe this is not correct? > > because the smart attributes the drive h

Re: [Smartmontools-database] smartctl-output

2010-07-15 Thread Frieder Ferlemann
Hi Manfred, Am 14.07.2010 23:23, schrieb Manfred Schwarb: > Am 13.07.2010 12:05, schrieb Frieder Ferlemann: >> I don't believe the OCZ-AGILITY2 is supported with the r3123 change:) > For me it works, why do you believe this is not correct? because the smart attributes the drive has available 1, 5

Re: [Smartmontools-database] smartctl-output

2010-07-14 Thread Manfred Schwarb
Am 13.07.2010 12:05, schrieb Frieder Ferlemann: > Hi, > > I don't believe the OCZ-AGILITY2 is supported with the r3123 change:) > > --- trunk/smartmontools/drivedb.h 2010/06/14 16:44:37 3121 > +++ trunk/smartmontools/drivedb.h 2010/07/11 22:35:19 3123 > @@ -170,7 +170,7 @@ > " -v 213,raw64" > }, >

Re: [Smartmontools-database] smartctl-output

2010-07-13 Thread Frieder Ferlemann
Hi, I don't believe the OCZ-AGILITY2 is supported with the r3123 change:) --- trunk/smartmontools/drivedb.h 2010/06/14 16:44:37 3121 +++ trunk/smartmontools/drivedb.h 2010/07/11 22:35:19 3123 @@ -170,7 +170,7 @@ " -v 213,raw64" }, { "OCZ Agility SSD", -"OCZ[

Re: [Smartmontools-database] smartctl-output

2010-06-22 Thread Frieder Ferlemann
seems the only attributes publicly known for the OCZ-AGILITY2 (SSD drive with sandforce controller) are 5 http://crystalmark.info/software/CrystalDiskInfo/manual-en/HealthStatus.html and 177 (Wear Range Delta) according to the changelog (for firmware 1.10). (177 would be newer than the firmware

[Smartmontools-database] smartctl-output

2010-06-14 Thread Thomas Langkamp
as mentioned on http://sourceforge.net/apps/trac/smartmontools/wiki/FAQ#MyATAdriveisnotinthesmartctlsmartddatabase linux-8yej:/home/thomas # smartctl -a /dev/sdb smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (openSUSE RPM) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sou