en-an-einem-canon-mx700-nutzen.html
Great! Thank you. But you should not write "Scannertasen" in the
headline :-)
--
Viele Gr??e
Werner Holtfreter
2011-07-15 13:41 wrote Werner Holtfreter:
> 2011-07-15 12:35 wrote Stef:
>
> > I have re-tuned MD5345/6228 scan area.
> > With latest source code version the bug is now fixed.
>
> Thank you very much! That is really high speed debugging!
>
> (I will enjoy i
2011-07-15 13:41 wrote Werner Holtfreter:
> 2011-07-15 12:35 wrote Stef:
>
> > I have re-tuned MD5345/6228 scan area.
> > With latest source code version the bug is now fixed.
>
> Thank you very much! That is really high speed debugging!
>
> (I will enjoy i
Hello Stef,
2011-07-15 12:35:43 schrieben Sie:
> I have re-tuned MD5345/6228 scan area.
> With latest source code version the bug is now fixed.
Thank you very much! That is really high speed debugging!
(I will enjoy it after distribution in Robert Ancell's ppa.)
--
Viele G
scanned.
Please give me detailed instruction to collect all needed info.
--
Viele Gr??e
Werner Holtfreter
r color scan in
such cases - I don't know why:
http://openlibrary.org/books/OL24347298M/Muhammedanisches_Recht_nach_Schafiitischer_Lehre
--
Viele Gr??e
Werner Holtfreter
he job in one step...
--
Viele Gr??e
Werner Holtfreter
greater a compressed file.)
gscan2pdf --> Preferences --> Blank threshold did not make a
difference. I need help to adjust the white level.
--
Viele Gr??e
Werner Holtfreter
Am Freitag, 2010-02-12 03:55:01 schrieb Robert Ancell:
> There is an easier way...
>
> I've made a PPA containing the latest GIT version of the SANE
> backends:
> https://edge.launchpad.net/~robert-ancell/+archive/sane-backends
Hi Robert,
thank you for your great service, it works fine and is a
h.debian.org
--
Viele Gr??e
Werner Holtfreter
In other case: Which switch on xsane
make a multipage-pdf?
Is the frontend topic in this mailing list?
--
Viele Gr??e
Werner Holtfreter
.995 is broken also in Suse11.0. My
result was readable only in some pdf-readers, in others not.
Today, I updated to xsane0.996 and can *not* reproduce this problem.
You should test with xsane0.996.
--
Viele Gr??e
Werner Holtfreter
Am Dienstag, 2008-08-26 20:45:01 schrieb stef:
> Le Wednesday 16 July 2008 16:39:18 Werner Holtfreter, vous avez
?crit?:
> > Am Montag, 30. Juni 2008 06:53:34 schrieb stef:
> > > the only difference I could spot is slightly different
> > > motor acceleration ta
to shake and does not move properly! The old problem.
--
Viele Gr??e
Werner Holtfreter
ening.
Done!
I hit CTRL-C in the first second after bad motor noise, but the
noise ended after 1/2 min and the prompt is back also after 1/2
min.
Therefore, in the next test, I made a copy in the bad moment:
cp scan.log scan.copy
then, I hit CTRL-C.
I send both files direct to you.
--
Viele Gr??e
Werner Holtfreter
n the UsbSnoop-window, but only 1 was
connected. Also, I have made a log with each device. Both works,
100 dpi, A4.
I hope it helps. Files are coming direct.
--
Viele Gr??e
Werner Holtfreter
ts with UsbSnoop:
1 all from plug in
2 prescan and scann
3 only scann, 100 dpi, gray, full A4.
Odd, the snoop-log grew while the mouse was moving, but not while
the scanning! Of course, the marker "installed" was set only on the
line "USB scanner".
(Files direct to you.)
--
Viele Gr??e
Werner Holtfreter
h the usb sniffer available at
> http://www.pcausa.com/Utilities/UsbSnoop/default.htm . Then send
> me the log file of a 100 pdi scan so that I check that your
> scanner has really the same hardware than mine.
The scanner works on windows. I sent the UsbSnoop.log direct to you.
--
Viele Gr??e
Werner Holtfreter
_DEVICE_CLASS is not set
# CONFIG_USB_DYNAMIC_MINORS is not set
# CONFIG_USB_SUSPEND is not set <-
# CONFIG_USB_OTG is not set
.
.
.
I'm not sure that it is, what you searching. I use:
Suse10.3 2.6.22.17-0.1-default
By the way: I've seen the same problem (scanner head starts to
shake) on a Window-PC. (My scanner was earlier on a other PC.)
--
Viele Gr??e
Werner Holtfreter
s to
shake and does not move properly. Sometimes means about 30 %.
(Log comes direct to you.)
--
Viele Gr??e
Werner Holtfreter
ub.
The same /other/ warnings are printed, but *usb* works!
"Only" the scanner don't move the head.
scan.log is very large, I send it not in the e-mail-list but direct.
--
Viele Gr??e
Werner Holtfreter
it
[genesys] sane_open: start (devicename = `genesys')
lt-scanimage: open of device genesys failed: Invalid argument
[genesys] sane_exit: start
[genesys] sane_exit: exit
--
Viele Gr??e
Werner Holtfreter
gt;
> > Do you mean I should test with my old Sane version or with the
> > new CVS?
>
> If the new CVS doesn't work, then please send me the log done
> with the newer version.
Sorry, Stef, I'm a stupid Suse10.3 user and install normally only
rpm. I'm still working with sane-backends1.0.19-0-pm.2 genesys.
If I should install a new CVS, then I would need instruction.
--
Viele Gr??e
Werner Holtfreter
happening ?
Do you mean I should test with my old Sane version or with the new
CVS?
--
Viele Gr??e
Werner Holtfreter
you for the completly commands.
The tar.gz.file is coming separat.
Other interested person welcome, please send a e-mail.
> ??BTW, is your model really a MD6228 ?
Yes, this is the number on the type label.
--
Viele Gr??e
Werner Holtfreter
*low* resolution and black/white for low data rate,
then the scanner head starts to shake and does not move properly!
All things are independent from the front-end and I have done tests
with Kooka, Xsane and Xscanimage.
Any ideas?
--
Viele Gr??e
Werner Holtfreter
26 matches