Re: [RE-wrenches] Lithium battery recommendation

2023-07-13 Thread Carl Hansen via RE-wrenches
 Peter,   I've also installed a few EG4 rack battery systems, they are working out well, tech support is easy to reach, not problems so far, customers like the price point. Standard 10 year warranty, company seems pretty solid, easy to communicate with.  Carl Hansen  Hansen&Sun Electric On

Re: [RE-wrenches] EG4 Equipment

2024-02-18 Thread Carl Hansen via RE-wrenches
Hi Howie,  I've continued to install EG4 LL V2 batteries for clients, I originally purchased a bank of EG4 V1's for my own system to experiment with before recommending them to clients, I quickly ended up with 7 clients with them and all the installs are performing without issues, these are a

Re: [RE-wrenches] EG4 Equipment

2024-02-18 Thread Carl Hansen via RE-wrenches
haelson On Sun, Feb 18, 2024 at 3:16 PM Carl Hansen via RE-wrenches wrote: Hi Howie,  I've continued to install EG4 LL V2 batteries for clients, I originally purchased a bank of EG4 V1's for my own system to experiment with before recommending them to clients, I quick

Re: [RE-wrenches] Ironridge ballasted BX on the ground

2024-04-12 Thread Carl Hansen via RE-wrenches
Nick,   In New Mexico it was popular on flat roof homes to lay down pressure treated 4x4's and lag your L-feet onto these then weight them down with cinder blocks filled with concrete, this would be an inexpensive temporary option.    Carl Hansen    Hansen&Sun Electric On 2024-04-09 2:58 P

Re: [RE-wrenches] sol ark battery

2024-10-10 Thread Carl Hansen via RE-wrenches
I've put in about Ten EG4 LL banks in the last 2 years, no problems with any of them, tech support is very good, they have a dedicated number for installers and someone always picks up, I like the digital screen with access to battery cell voltages, cell temps, amps, battery voltage and %.  The

Re: [RE-wrenches] EG4 Lithium absorb time in open loop configuration

2024-11-07 Thread Carl Hansen via RE-wrenches
Jeremy,   Signature solar techs have told me 30 min.  Carl Hansen  Hansen&Sun Elect. On 2024-11-07 6:31 AM, Jeremy Rodriguez via RE-wrenches wrote: Wrenches Signature Solar has no absorb time recommendation for their rack mount EG4s ! I’m setting up a system with a 1200 ah battery stack. Six

Re: [RE-wrenches] EG4 Mini Split

2025-06-19 Thread Carl Hansen via RE-wrenches
There are a few of these EG4 solar hybrid units in my area, all installed by homeowners on Off Grid homes,  they have to be connected to the homes AC system so that when the sun isn't shining they will run just as well off 120vac. I'm assuming when the sun is shining the outdoor and indoor unit