Re: [RE-wrenches] Wire protection for ground mount

2015-04-17 Thread Jason Szumlanski
What are you screwing the aluminum into? Any chance of getting a picture? On Fri, Apr 17, 2015 at 9:08 AM, Matt Sherald wrote: > Adam, > > I've used aluminum perforated sheet metal in the past. It matches the > other aluminum on the ground mount and it can be zipped up with self > drilling sc

Re: [RE-wrenches] Wire protection for ground mount

2015-04-17 Thread Dave Click
I think someone here long ago recommended solarscrim.com; when I recommended it to three contractors I heard: 1) "awesome, I just bought some and I'll use this on every project!" 2) "too expensive, I'm getting some tennis court screening on my own and doing it myself." 3) "too expensive, I'm g

Re: [RE-wrenches] Wire protection for ground mount

2015-04-17 Thread Glenn Burt
Just be sure to properly bond it to ground per 250.8 & 12, and 250.4. Sincerely, Glenn Burt Sent from my 'smart' phone so please excuse grammar and typos. -Original Message- From: "Matt Sherald" Sent: ‎4/‎17/‎2015 9:08 To: "RE-wrenches" Subject: Re:

Re: [RE-wrenches] Wire protection for ground mount

2015-04-17 Thread Matt Sherald
Adam, I've used aluminum perforated sheet metal in the past. It matches the other aluminum on the ground mount and it can be zipped up with self drilling screws. Looks pretty sharp when it is done - kinda like it was meant to be there all along. -Matt On Fri, Apr 17, 2015 at 7:20 AM, AE Solar

[RE-wrenches] Wire protection for ground mount

2015-04-17 Thread AE Solar
Hey Wrenchers, Does anyone have suggestions for netting/protecting wires behind a ground mount (for keeping hands out of there...not animals). I have seen quite a few home-made'ish looking options on systems around here (screwing hardware cloth onto the back of frames/racking, etc) but am looking