Re: [RE-wrenches] Braided grounding wire

2008-08-23 Thread North Texas Renewable Energy Inc
orth Texas Renewable Energy Inc 817.917.0527 [EMAIL PROTECTED] www.ntrei.com - Original Message - From: [EMAIL PROTECTED] To: RE-wrenches Sent: Friday, August 22, 2008 10:41 AM Subject: [RE-wrenches] Braided grounding wire Anybody know a source for braided grounding wire

Re: [RE-wrenches] Braided grounding wire

2008-08-23 Thread R. Walters
Hi August; For any tilt adjustable or tracking system, that solid 10(or 6) will strain harden and break. (We do a lot of pole mounts.) We tried stranded 6, but found the tinned braid to be more corrosion resistant at the connection point to the aluminum. It looks very commercial/ professiona

Re: [RE-wrenches] Braided grounding wire

2008-08-23 Thread August Goers
ECTED] www.luminalt.com - Original Message From: jay peltz <[EMAIL PROTECTED]> To: RE-wrenches Sent: Friday, August 22, 2008 6:28:33 PM Subject: Re: [RE-wrenches] Braided grounding wire One issue that has been troubling me is the 1 size fits all. We live and work in many reall

Re: [RE-wrenches] Braided grounding wire

2008-08-23 Thread Tom DeBates
have difficulty locating this product, I have an "extra" 250' spool. good luck, Tom Tom DeBates Habi-Tek 524 Summit St. Geneva,IL. 60134 630-262-8193 fax 630-262-1343 --- On Fri, 8/22/08, [EMAIL PROTECTED] <[EMAIL PROTECTED]> wrote: > From: [EMAIL PROTECTED] <[EMA

Re: [RE-wrenches] Braided grounding wire

2008-08-22 Thread Sky Sims
biz > 220 County Road 522 > Manalapan, NJ 07726 > 732-462-3858 toll free)866-759-7652 fax)732-462-3962 > > > -Original Message- > From: [EMAIL PROTECTED] > [mailto:[EMAIL PROTECTED] On Behalf Of R. > Walters > Sent: Friday, August 22, 2008 2:01 PM > To: RE-w

Re: [RE-wrenches] Braided grounding wire

2008-08-22 Thread jay peltz
2 -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of R. Walters Sent: Friday, August 22, 2008 2:01 PM To: RE-wrenches Subject: Re: [RE-wrenches] Braided grounding wire We don't use braided for direct burial. We use it to bond to the array, run with th

Re: [RE-wrenches] Braided grounding wire

2008-08-22 Thread jay peltz
Hi Robert, Yes quick cable # 50401 for 100' roll. Size is #4 jay peltz power On Aug 22, 2008, at 5:38 PM, robert ellison wrote: Try Quick Cable, seems that they have it if I remember correctly. Bob On Fri, Aug 22, 2008 at 11:41 AM, <[EMAIL PROTECTED]> wrote: Anybody know a source for braide

Re: [RE-wrenches] Braided grounding wire

2008-08-22 Thread robert ellison
Try Quick Cable, seems that they have it if I remember correctly. Bob On Fri, Aug 22, 2008 at 11:41 AM, <[EMAIL PROTECTED]> wrote: > Anybody know a source for braided grounding wire? Internet search > fruitless.. > > Holt E. Kelly > Holtek Fireplace & Solar Products > 500 Jewell Dr. > Waco,

Re: [RE-wrenches] Braided grounding wire

2008-08-22 Thread Sky Sims
al Systems http://www.ecologicalsystems.biz 220 County Road 522 Manalapan, NJ 07726 732-462-3858 toll free)866-759-7652 fax)732-462-3962 -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of R. Walters Sent: Friday, August 22, 2008 2:01 PM To: RE-wrenches Subject: Re: [RE-wr

Re: [RE-wrenches] Braided grounding wire

2008-08-22 Thread R. Walters
We don't use braided for direct burial. We use it to bond to the array, run with the PV wires, and switch to regular copper as soon as we go into conduit at the first J box. We zip tie it together in a bundle with all the MC cables. [EMAIL PROTECTED] Braid tends to "wick" water, and we

Re: [RE-wrenches] Braided grounding wire

2008-08-22 Thread R. Walters
un.com/ForumVB/ .. - Original Message - From: [EMAIL PROTECTED] To: RE-wrenches Sent: Friday, August 22, 2008 8:41 AM Subject: [RE-wrenches] Braided grounding wire Anybody know a source for braided grounding wire? Internet search fruitless..

Re: [RE-wrenches] Braided grounding wire

2008-08-22 Thread Wind-sun.com
Wind & Sun - Electricity From The Sun .. - Original Message - From: "Walt Ratterman" <[EMAIL PROTECTED]> To: "RE-wrenches" Sent: Friday, August 22, 2008 8:

Re: [RE-wrenches] Braided grounding wire

2008-08-22 Thread Walt Ratterman
i.org Walt Ratterman Sent Wirelessly -Original Message- From: "Wind-sun.com" <[EMAIL PROTECTED]> Date: Fri, 22 Aug 2008 08:46:28 To: RE-wrenches Subject: Re: [RE-wrenches] Braided grounding wire ___ List sponsored by Home Power

Re: [RE-wrenches] Braided grounding wire

2008-08-22 Thread Peter Parrish
You might give the guys at NorthWest Data Comm, Reno, NV a call. Peter T. Parrish, _ From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of [EMAIL PROTECTED] Sent: Friday, August 22, 2008 8:41 AM To: RE-wrenches Subject: [RE-wrenches] Braided grounding wire Anybody know

Re: [RE-wrenches] Braided grounding wire

2008-08-22 Thread Wind-sun.com
[RE-wrenches] Braided grounding wire Anybody know a source for braided grounding wire? Internet search fruitless.. Holt E. Kelly Holtek Fireplace & Solar Products 500 Jewell Dr. Waco,Tx. 76712 254-751-9111 254-228-9621 (cell) [EMAIL PROTECTED] - Original

[RE-wrenches] Braided grounding wire

2008-08-22 Thread holtek
Anybody know a source for braided grounding wire? Internet search fruitless.. Holt E. Kelly Holtek Fireplace & Solar Products 500 Jewell Dr. Waco,Tx. 76712 254-751-9111 254-228-9621 (cell) [EMAIL PROTECTED] - Original Message - From: Kurt Albershardt To: RE-wrenches Sent: