On 2013-07-12T08:32:53, Andrew Beekhof wrote:
> Some parts of cman - dlm specifically, insist on fencing anyway.
> If you're not planning on using gfs, you could investigate turning off the
> dlm.
I keep thinking that those parts should then fail cleanly instead of
fuzzy errors. i.e., not start
On 16/07/2013, at 11:59 PM, K Mehta wrote:
> Hi,
> Where can I find information about which versions of pacemaker, cman and
> corosync are compatible with each other ?
I don't think such a document exists.
What distro are you using? The best option is usually to use whatever they
provide.
_
On 16/07/13 09:03, K Mehta wrote:
I have a two node test cluster running with CMAN plugin. Fencing is not
configured.
Andrew spoke to the pacemaker stuff. I want to reiterate what he said on
fencing though. Fencing *must* be used with cman. If fenced calls a
fence, nothing else will happen un
On 16/07/2013, at 11:03 PM, K Mehta wrote:
> I have a two node test cluster running with CMAN plugin. Fencing is not
> configured.
Thats problem 1
> I see that vsanqa7 sends a message to vsanqa8 to shutdown.
> However, it is not clear why vsanqa7 takes this decision.
It looks like you're hit
On 17/07/2013, at 2:33 AM, Tero M wrote:
> Hi,
>
> is it possible to set up network interface as resource so that Pacemaker
> enables and disables it as needed? I have need to set up network
> interface that has specific MAC address but IP address is determined
> with dhcp.
If you can script i
Hi,
OK, so I was a little hasty in announcing success, because the issue
only occurs when all three of my nodes are active.
With DRBD resource A managed by nodes c3 and c4, and DRBD resource B
managed by nodes c4 and c5, I can reliably cause a never-ending flapping
failure by performing the steps
On 07/15/13 09:02, Alex Hemsley wrote:
Hi,
We have some telephony failover equipment (Digium R850 appliances) that came
with a sample Pacemaker configuration using the “crm configure load update”
method. Now we are using Fedora 18 Kernel 3.9.4-200 pacemaker 1.1.9-0.1, so pcs
is the preferred man
Hi,
is it possible to set up network interface as resource so that Pacemaker
enables and disables it as needed? I have need to set up network
interface that has specific MAC address but IP address is determined
with dhcp.
Tero M
___
Pacemaker mailing
Hi,
Probably safe to disregard this issue... I found I was somehow not
building the latest 1.1.9. After building and installing 1.1.9-cad5efc
the problem appears to have gone away.
On 07/15/2013 05:25 PM, Matthew O'Connor wrote:
> I have run into a strange problem with a DRBD resource migrating
Hi,
Where can I find information about which versions of pacemaker, cman and
corosync are compatible with each other ?
Regards,
Kiran
___
Pacemaker mailing list: Pacemaker@oss.clusterlabs.org
http://oss.clusterlabs.org/mailman/listinfo/pacemaker
Proje
On 16/07/2013, at 7:04 PM, Kazunori INOUE wrote:
> (13.07.15 11:00), Andrew Beekhof wrote:
>>
>> On 12/07/2013, at 6:28 PM, Kazunori INOUE
>> wrote:
>>
>>> Hi,
>>>
>>> I'm using pacemaker-1.1.10.
>>> When a pacemaker's process crashed, the node is sometimes fenced or is not
>>> sometimes f
On 16/07/2013, at 2:05 AM, "Howley, Tom" wrote:
> Hi Andrew,
>
> Thanks for the reply. I have a couple of more questions below. I have seem to
> have two main problems: isolated node updating CIB; corosync behaviour to
> ifdown.
>
>> Why isn't your normal fencing device working?
> My normal
On 15/07/2013, at 8:56 PM, Mistina Michal wrote:
> Hi Andrew.
>
> Here is the ommited /var/log/messages with stonigh-ng sections.
>
> Jul 15 09:53:38 PCMK1 stonith-ng[1538]: notice: stonith_device_action:
> Device vm-fence-pcmk2 not found
> Jul 15 09:53:38 PCMK1 stonith-ng[1538]: info: s
On 16/07/2013, at 5:37 PM, Johan Huysmans wrote:
> Hi,
>
> Attached is some more logging of the failed diff:
>
> I hope this is sufficient information to help investigate the problem.
Does /tmp also contain files called:
"diff:original"
"diff:input"
"diff:new"
?
Those would be very useful.
I have a two node test cluster running with CMAN plugin. Fencing is not
configured. I see that vsanqa7 sends a message to vsanqa8 to shutdown.
However, it is not clear why vsanqa7 takes this decision.
===/var/log/messages=
Node vsanqa7
Jul 15 08
On 2013-07-15T06:27:47, Zvi wrote:
> is there an option to configure corosync to use serial?
No. corosync no longer supports serial.
Regards,
Lars
--
Architect Storage/HA
SUSE LINUX Products GmbH, GF: Jeff Hawn, Jennifer Guild, Felix Imendörffer, HRB
21284 (AG Nürnberg)
"Experience is t
(13.07.12 22:48), emmanuel segura wrote:
Hi
try to disable selinux
Though I tried it, the result did not change.
+++
Jul 12 16:46:10 dev1 setroubleshoot: SELinux is preventing /usr/bin/virsh
from getattr access on the file
(13.07.15 11:00), Andrew Beekhof wrote:
On 12/07/2013, at 6:28 PM, Kazunori INOUE wrote:
Hi,
I'm using pacemaker-1.1.10.
When a pacemaker's process crashed, the node is sometimes fenced or is not
sometimes fenced.
Is this the assumed behavior?
Yes.
Sometimes the dev1 respawns the process
Hi,
Attached is some more logging of the failed diff:
I hope this is sufficient information to help investigate the problem.
Thx.
Johan
On 15-07-13 03:02, Andrew Beekhof wrote:
On 11/07/2013, at 5:09 PM, Johan Huysmans wrote:
Hi,
Sorry about the missing info, here it is:
OS: CentOS 6.4
Co