Re: [Openocd-development] Help with communication problems - old config file translation

2009-04-08 Thread Jesus Sanchez-Palencia
Could you send me the config file you used ? Thanks, jesus 2009/4/8 Magnus Lundin > Hi, > > I have resently made some test on the same board but with a ft2232 based > interface. > The configuration that works best so far uses: > > #use combined on interfaces or targets that can't set TRST/SRST

Re: [Openocd-development] Help with communication problems - old config file translation

2009-04-07 Thread Magnus Lundin
Hi, I have resently made some test on the same board but with a ft2232 based interface. The configuration that works best so far uses: #use combined on interfaces or targets that can't set TRST/SRST separately reset_config trst_and_srst srst_pulls_trst jtag_nsrst_delay 10 jtag_khz 1000 The LPC2

[Openocd-development] Help with communication problems - old config file translation

2009-04-07 Thread Jesus Sanchez-Palencia
Hey guys, I'm trying to "translate" and old config file for LPC-E2124 (Olimex), because it has some deprecated functions. I'm sending attached both config files, the old one and the one I'm working on right now. I've already managed to communicate with the board, but something still seems to be w