* Thuban le [02-12-2018 19:16:09 +0100]:
> Hi,
> I need help to write a correct rule in pf.conf.
>
> I want :
>
> A -> B --> web
>
> The appearing IP of A is the B's one on the web.
>
> I managed to configure iked on A and B using default pubkeys according
> to Stuart Henderson advic
On Thu, Dec 06, 2018 at 01:26:12PM +0900, 岡本健二 wrote:
> in-current means stable 6.4?
>
No. Look in the FAQ. Look at the running -current page
Look at what release -> stable is.
Run -current only if you need something new, are developing base/ports
or wish to help test the software/hardware being
Hi all,
i just wanted to warn people not to buy X710-DA4 and try to insert it in
Dell R420. You can insert it in Dell R620 just fine.
nic - http://kosjenka.srce.hr/~hrvoje/nic.jpg
r420 pci slot - http://kosjenka.srce.hr/~hrvoje/r420-pci.jpg
On other hand don't put chinese X710-DA2 or something
It seems a bug in xlock program also.
When exit from xlock getting this:
...
/usr/X11R6/bin/xlock
(EE) Segmentation fault at address 0xac986a95000
(EE)
Fatal server error:
(EE) Caught signal 11 (Segmentation fault). Server aborting
(EE)
(EE)
Please consult the The X.Org Foundation support
...
On
On 2018-12-06, Thuban wrote:
> * Thuban le [02-12-2018 19:16:09 +0100]:
>> Hi,
>> I need help to write a correct rule in pf.conf.
>>
>> I want :
>>
>> A -> B --> web
>>
>> The appearing IP of A is the B's one on the web.
>>
>> I managed to configure iked on A and B using default pub
Hi,
i am trying to use relayd as an outbound proxy. I am following the
manual page and also the book "Httpd and Relayd Mastery". I did this on
the latest release 6.4 and also on the latest snapshot to make sure this
was not already fixed somewhere. I am on amd64.
My relayd config looks like t
Hi,
i found this old thread and i have the same problem. i need an active
timeout of the netflow data.
i found this patch
http://marc.info/?l=openbsd-misc&m=124661838923498&w=2
which i can set the "set timeout pflowexport 60" for example
Have anyone tried that ?
Sebastian Benoit wrote:
howev
Folks,
Fiddling with a basic iked configuration:
ikev2 roadwarrior \
from any to 172.31.0.0/20 \
local 172.31.15.102 peer any \
config address 172.31.0.224/28 \
config protected-subnet 172.31.0.0/20 \
tag "IKED"
I created a ca and certs using ikectl using hostnames.
When I
After changing X Display Manager to xenodm + spectrwm as win manager I
have an additional terminal load just after xenodm login.
I've disabled 'xconsole' in /etc/X11/xenodm/Xsetup_0 by commenting it.
# cat ~/.xsessinon
export ENV=$HOME/.kshrc
xsetroot -solid grey &
xterm -bg black -fg white +sb &
Hi,
I'm having no success to scan negative film on my Canoscan 9000F Mark
II. I'm using OpenBSD 6.4 stable, sane-backends 1.0.27p3, and xsane
0.999p4.
http://www.sane-project.org/sane-mfgs.html says that support for this
scanner is "complete". The scanner works fine on Mac OS X.
The scanimage co
On 12/4/2018 2:12 PM, Charles A Daniels wrote:
Closing the lid on the T430 causes OpenBSD to suspend, as per my
setting for machdep.lidaction=1. This usually works as expected, but
occasionally I take my laptop out of my bag to find it sitting on the
xenodm login screen, not suspended, with the l
Thomas Boernert(m...@tbits.net) on 2018.12.06 18:11:17 +0100:
> Hi,
>
> i found this old thread and i have the same problem. i need an active
> timeout of the netflow data.
>
> i found this patch
> http://marc.info/?l=openbsd-misc&m=124661838923498&w=2
> which i can set the "set timeout pflowexp
Hi Benno,
have you tried the diff by yourself ?
Thanks
Thomas
Am 2018-12-06 21:14, schrieb Sebastian Benoit:
Thomas Boernert(m...@tbits.net) on 2018.12.06 18:11:17 +0100:
Hi,
i found this old thread and i have the same problem. i need an active
timeout of the netflow data.
i found this pat
I'm using acme also on OpenBSD.
I don't know any better editor than that.
Of course, where acme cannot use, such as cui only, I use ed.
Kenji
2018年12月6日(木) 21:38 Chris Bennett :
> On Thu, Dec 06, 2018 at 01:26:12PM +0900, 岡本健二 wrote:
> > in-current means stable 6.4?
> >
>
> No. Look in the FAQ.
Hello,
Im running a router with multiple ips on an interface using the
inet alias
issue:
when commenting out configured aliases on hostname.if
after running sh /etc/netstart vio4
if you run ifconfig vio4 after the restart of the interface
the old aliases that were commented still appear in ifco
I checked mesa-18.3.0 sources under src/gallium/drivers/r600 and compared
with those
of xenocara. File names are all same, however, individual sizes are very
different for
most of those, which would not permit me to copy those to xenocara...
Kenji
2018年12月6日(木) 15:14 岡本健二 :
> also, it stull ha
16 matches