Re: monitoring raid with mpi

2007-04-05 Thread David Gwynne
yeah, this is akward... i guess i should plug my mpi in again. On 05/04/2007, at 2:50 AM, Thierry Lacoste wrote: On Wednesday 04 April 2007 17:37, Chris Black wrote: Thierry Lacoste wrote: I installed OpenBSD on a Dell PowerEdge with a raid1 array controlled by a SAS 5iR controller thanks to

Re: monitoring raid with mpi

2007-04-04 Thread Thierry Lacoste
On Wednesday 04 April 2007 17:37, Chris Black wrote: > Thierry Lacoste wrote: > > I installed OpenBSD on a Dell PowerEdge with > > a raid1 array controlled by a SAS 5iR controller > > thanks to the new mpi driver. > > > > mpi0 at pci2 dev 8 function 0 "Symbios Logic SAS1068" rev 0x01: irq 5 > > scs

Re: monitoring raid with mpi

2007-04-04 Thread Chris Black
Thierry Lacoste wrote: > I installed OpenBSD on a Dell PowerEdge with > a raid1 array controlled by a SAS 5iR controller > thanks to the new mpi driver. > > mpi0 at pci2 dev 8 function 0 "Symbios Logic SAS1068" rev 0x01: irq 5 > scsibus0 at mpi0: 63 targets > sd0 at scsibus0 targ 0 lun 0: SCSI3 0/

monitoring raid with mpi

2007-04-04 Thread Thierry Lacoste
I installed OpenBSD on a Dell PowerEdge with a raid1 array controlled by a SAS 5iR controller thanks to the new mpi driver. mpi0 at pci2 dev 8 function 0 "Symbios Logic SAS1068" rev 0x01: irq 5 scsibus0 at mpi0: 63 targets sd0 at scsibus0 targ 0 lun 0: SCSI3 0/direct fixed sd0: 69618MB, 69618 cyl