Actually you can define a model 27 or 54 in a IBM DS8k with a number of cilinders not multiple of 1.113 (1 disk model-1 or 1 extent), but the remaining space will be wasted For instance in my shop there are defined model 27 with 32760 cilinders, 29,4 extents. The DS8k use 30 extents to define this

Re: DASD Model-27 & 54 implementation

2015-01-21 Thread R.S.
W dniu 2015-01-21 o 17:30, Tom Marchant pisze: On Wed, 21 Jan 2015 15:11:13 +, Vernooij, CP (ITOPT1) - KLM wrote: IIRC, all volumes must be a multiple of cyls, a 3390 model 1. Really? I didn't think there was such a restriction. There is such restriction, but not on z/OS side. It is

Re: DASD Model-27 & 54 implementation

2015-01-21 Thread Mike Schwab
IBM DS* imposed this. It divides the space into Mod 1 chunks, then each volume uses one or more chunks for its space, and you can add a Mod 1 chunk to a volume. On Wed, Jan 21, 2015 at 10:30 AM, Tom Marchant <000a2a8c2020-dmarc-requ...@listserv.ua.edu> wrote: > On Wed, 21 Jan 2015 15:11:13 +0

Re: DASD Model-27 & 54 implementation

2015-01-21 Thread Mark Zelden
On Wed, 21 Jan 2015 15:09:38 +, Bob Shannon wrote: >>I think there are not special considerations with model 27 or model 54.Those >>dasd are just 3390-9 devices with a bigger size. >Correct. You aren't limited to Mod 27s or Mod 54s. As an example one can >define a Mod-15. The "mod" is

Re: DASD Model-27 & 54 implementation

2015-01-21 Thread Tom Marchant
On Wed, 21 Jan 2015 15:11:13 +, Vernooij, CP (ITOPT1) - KLM wrote: >IIRC, all volumes must be a multiple of cyls, a 3390 model 1. Really? I didn't think there was such a restriction. -- Tom Marchant -- For IBM-MAIN su

Re: DASD Model-27 & 54 implementation

2015-01-21 Thread Vernooij, CP (ITOPT1) - KLM
al Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Gonzalo Cengotita Sent: 21 January, 2015 15:51 To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: DASD Model-27 & 54 implementation Hi, I think there are not special considerations with model 27 or model

Re: DASD Model-27 & 54 implementation

2015-01-21 Thread Bob Shannon
>I think there are not special considerations with model 27 or model 54.Those >dasd are just 3390-9 devices with a bigger size. Correct. You aren't limited to Mod 27s or Mod 54s. As an example one can define a Mod-15. The "mod" is based on the size of the volume. Anything GT a Mod-9 and LT a Mo

Re: DASD Model-27 & 54 implementation

2015-01-21 Thread Gonzalo Cengotita
Hi, I think there are not special considerations with model 27 or model 54. Those dasd are just 3390-9 devices with a bigger size. Regards, Gonzalo Cengotita 2015-01-21 12:23 GMT+01:00 Buckton, T. (Theo) : > Hi, > > Please refer me to documents containing notes on implementing dasd 3390 > model

Re: DASD Model-27 & 54 implementation

2015-01-21 Thread Elardus Engelbrecht
Buckton, T. (Theo) wrote: >Please refer me to documents containing notes on implementing dasd 3390 >model27 & 54 - considerations and configuring DFSMS. We are running z/OS 2.1 About z/OS v2.1, SMS, device management and emulation (with HCD and SMS) look and search in http://www-03.ibm.com/