On Thu, 8 Dec 2022 at 19:22, Timothy Sipples wrote:
> I'm a bit confused. IBM Trusted Key Entry (TKE) Workstation microcode
> updates are performed by an IBM Customer Engineer (CE). If you have
> separation of duties-related concerns that's perfectly fine, but you still
> should have IBM CE assis
Not my area of expertise. However, I came across the following in a TKE
presentation.
Format your IBM supported USB memory for Trusted Key Entry data (TKE Data).
This suggests that it's some special format and can only be done on a TKE
itself.
It seems for some reason you are trying to load
I'm a bit confused. IBM Trusted Key Entry (TKE) Workstation microcode updates
are performed by an IBM Customer Engineer (CE). If you have separation of
duties-related concerns that's perfectly fine, but you still should have IBM CE
assistance available — you can ask the CE, basically, and then d
The easiest option would be to create a new environment and volume(s)
for test and development and IPL to the new volume(s), leaving the
production alone, and disable some volumes if you need to reclaim
space.
On Thu, Dec 8, 2022 at 1:16 PM Michael Babcock wrote:
>
> We have a 3 system plex, with
Looks like the answer is no to your question.
-
Although, FENCE=(ACTIVE=YES,VOLUMES=nnn) indicates that JES2 will fence to nnn
volumes in most cases more than one nnn volume can be used in certain
situations such as when spool volumes fill or if the job obtains spool space on
different syste
Food for thought - separate MAS for each environment, but same
SYSPLEX. Though better to have each environment in separate SYSPLEX
and MAS. (That also allows better separation for implementing
changes to each environment.
Michael)
At 01:16 PM 12/8/2022, Michael Babcock wrote:
Content-Trans
Has anyone used the SPOOL statement in JES2PARM to set affinity to a
particular LPAR for spool? Apparently, you set spool volumes A, B, C, D
to have affinity with PROD and set E, F, G, H to have affinity with
DEV. This seems to have the effect of "fencing" DEV to certain spool
volumes. I c
I've been there before with management on issues similar, but like any
child - they'll quickly move on, oh look a squirrel' and this will give
you time to get automation setup correctly and you can test with a lower
threshold and provide the results to them if they ask, IF THEY ASK :)
JMHO
Ca
We have CA-OPS and have put things in place but management isn’t mainframe
literate and may be adamant about splitting.Up to me, I would move on
to something more pressing.
Thanks for the responses.
On Thu, Dec 8, 2022 at 1:24 PM Allan Staller <
0387911dea17-dmarc-requ...@listserv.ua.edu>
Yes, a JES2 cold start with newly defined/allocated spool and checkpoint
datasets will be needed. Have you looked into setting default estimates in
JES2PARM, bytes, lines, pages, with OPT=1 to cancel jobs that exceed your
limits?
Mark Jacobs
Sent from ProtonMail, Swiss-based encrypted email.
I think maybe all of us have seen something like this over the years, we
control this via OPS (automation) two fold
1) pause - quiesce the workload and notify operations / systems when the
threshold reaches 80%
2) (we don't have a need) but just in case, automation will add a spool
volume we
We don't have a plex so I can't answer your question directly, but do you have
any kind of automated console monitoring? We set up a rule so that if test
jobs go over a certain percent of spool space, we just automatically cancel and
purge them, no questions asked. We implemented this after a
Classification: Confidential
Rather than split the spool, (no cold start required IIRC, it might be more
prudent to limit the amount of output a job can create.
Look up $ESTLNCT(?) in the JES2 manual; Set an appropriate Count and specify
option 2.
When the job exceeds the defined limit (more
We have a 3 system plex, with two of those systems, DEV and PROD, in a
JES2 MAS. We had an incident recently where a development job got into
a loop and used up all spool. This in turn, caused our PROD system to
come to, basically, a screeching halt.
Management wants to investigate removing
I've never worked with a TKE, but I've had to plug into HMC's, DS8000's,
and others such as IBM 2421 SKLM's, and I believe I've always had to
format my USB as FAT32 on Windows.
On 12/7/2022 12:00 PM, Radoslaw Skorupka wrote:
I need to update microcode in my TKE.
Unfortunately I used USB pendri
TKE is a closed appliance and only an IBM SSR is allowed to install updates on
a TKE.
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Radoslaw Skorupka
Sent: Wednesday, December 7, 2022 3:01 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: [EXTERNAL] TKE and USB filesystem
Sample for Multiple LPARS sharing OSAs Make sure there are enough data UCBs
FIBRE 10GB OSAD EXPRESS CONFIGURATION
Researching the configuration of OSAD 10Gb configuration resulted in the
development of the following configuration parameters for customer’s setup on a
single Z14 machine.
The
Ed,
I think OSA acts like a switch, so you can share it between Lpars. I do use
z/vm vswitch since we have only one processor on zpdt, but I have sen that
in previous life.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuo
Am 08.12.22 um 17:44 schrieb Jim Elliott:
I am sure that z/OS must provide a function equivalent to z/VM's Link
Aggregation (where you can share physical OSA ports in a VSwitch), but lots
of Google searches are not helping me. Any suggestions?
Link aggregration is on layer2 (ethernet) and used
I don't recall the specifics but in Z/os you can define the OSA's and
ports, and depending on the OSA-Express card you have, some have 4 ports
per card, some have only 2, and if IIRC, on a z15 one for one, but you
can share across LPARS defined in your IOGEN, and use a device /
interface stat
Please explain a bit more what you are trying to do...
Are you trying to share an OSA link with multiple LPARs?
Are you trying to have multi OSA links for a single LPARs use like through a
VIPA?
A switch might not be needed.
Also, what version of Z and z/OS
Thanks
-
I am sure that z/OS must provide a function equivalent to z/VM's Link
Aggregation (where you can share physical OSA ports in a VSwitch), but lots
of Google searches are not helping me. Any suggestions?
Jim Elliott
Senior IT Consultant - GlassHouse Systems Inc.
22 matches