Hi everyone,
I want to calculate the LJ potential with different Cut-off for simulation
in a reduced unit (LJ unit).
For example, the cut-off for LJ potential of A-A, A-B, and B-B is 1.12246
(repulsive), 1.12246, and 2.5 (attractive, respectively;
However, it seems that the Cut-off only can
On 4/19/13 2:25 PM, Nuria Cirauqui Diaz wrote:
Hi all,
I am trying to run a simulation of a protein in a water-vacuum-water box,
which simulates quite well the membrane environment. I did it some years
ago in amber, but know I am trying in grommacs and got the following answer
when I try to ru
Hi all,
I am trying to run a simulation of a protein in a water-vacuum-water box,
which simulates quite well the membrane environment. I did it some years
ago in amber, but know I am trying in grommacs and got the following answer
when I try to run the fist "mdp" file:
ERROR: The cut-off length i
O.K thanks
Justin Lemkul wrote:
>
>
> On 10/5/12 8:15 AM, Gavin Melaugh wrote:
>> Is there any need to use the r2 option the ?
>>
>
> That option is not relevant here. It is undocumented in the current
> release, but the help description has been updated for the next release:
>
> http://redmine.g
On 10/5/12 8:15 AM, Gavin Melaugh wrote:
Is there any need to use the r2 option the ?
That option is not relevant here. It is undocumented in the current release,
but the help description has been updated for the next release:
http://redmine.gromacs.org/projects/gromacs/repository/revisi
Is there any need to use the r2 option the ?
Justin Lemkul wrote:
>
>
> On 10/5/12 7:39 AM, Gavin Melaugh wrote:
>> Hi Justin
>>
>> Thanks, that's what I thought. Is there a need to define a
>> hydrogen-acceptor distance as well. I read in a few articles that this
>> was the case, usually 0.25nm ?
On 10/5/12 7:39 AM, Gavin Melaugh wrote:
Hi Justin
Thanks, that's what I thought. Is there a need to define a
hydrogen-acceptor distance as well. I read in a few articles that this
was the case, usually 0.25nm ?
One can define hydrogen bonds in a number of ways, but a D-A distance of 0.35 n
Hi Justin
Thanks, that's what I thought. Is there a need to define a
hydrogen-acceptor distance as well. I read in a few articles that this
was the case, usually 0.25nm ?
Cheers
Gavin
Justin Lemkul wrote:
>
>
> On 10/5/12 7:20 AM, Gavin Melaugh wrote:
>> Hi all
>>
>> I am using g_hbond to calcu
On 10/5/12 7:20 AM, Gavin Melaugh wrote:
Hi all
I am using g_hbond to calculate the number of hydrogen bonds in an
alcohol system. I am using
the following command:
g_hbond -f traj.trr -nonitacc
I am slightly confused about the cut off r. Using the above command, is
the default cut-off r (0.
Hi all
I am using g_hbond to calculate the number of hydrogen bonds in an
alcohol system. I am using
the following command:
g_hbond -f traj.trr -nonitacc
I am slightly confused about the cut off r. Using the above command, is
the default cut-off r (0.35nm) for the donor-acceptor distance or the
Dear Gromacs users,
I am using GROMACS 3.3.2. I have a problem in setting the cut off of my MD-run.
I want to see the interaction between some small atoms keeping them inside a
periodic box without adding any solvent; i.e interaction between the atoms in
the vacuum.
I have a total of 18-25 atoms
nishap.pa...@utoronto.ca wrote:
I see what you mean, so say if I am doing RDF, the values beyond 9A
would be bogus?
To a large extent, probably, but I don't think that I can say that absolutely
without context. For example, you've only shown us rvdw, what about rcoulomb?
If it is longer
I see what you mean, so say if I am doing RDF, the values beyond 9A
would be bogus?
Quoting "Justin A. Lemkul" :
nishap.pa...@utoronto.ca wrote:
Hello,
I wanted to know, if say my box is 30A (cubic) and if I set my
cut-off lengths i.e. rvdw-switch = 0.8 and rvdw =0.9 , does that
nishap.pa...@utoronto.ca wrote:
Hello,
I wanted to know, if say my box is 30A (cubic) and if I set my
cut-off lengths i.e. rvdw-switch = 0.8 and rvdw =0.9 , does that mean,
the simulation will cut-0ff at 9A? Should I be changing that to 1.5nm
(to get half the box cut-off)? I am a little
Hello,
I wanted to know, if say my box is 30A (cubic) and if I set my
cut-off lengths i.e. rvdw-switch = 0.8 and rvdw =0.9 , does that mean,
the simulation will cut-0ff at 9A? Should I be changing that to 1.5nm
(to get half the box cut-off)? I am a little confused about that.
Thanks.
15 matches
Mail list logo