Re: Issues with bxe NIC

2018-02-01 Thread Rainer Duffner
> Am 01.02.2018 um 21:21 schrieb Matt Joras : > > This is one of many issues we have seen with the NetXtreme II device. After I had problems with lagg(4) (well, it just didn’t work at all), I opened a PR (or I found an existing one) and added to it. I didn’t even really realize it was bxe(4)

Re: Issues with bxe NIC

2018-02-01 Thread Matt Joras
On Thu, Feb 1, 2018 at 6:56 AM, Marius Halden wrote: > On Thu, Feb 1, 2018, at 15:17, Marius Halden wrote: > [...] > Is this a hardware or a driver issue? This is one of many issues we have seen with the NetXtreme II device. After a lot of back and forth (1.5 years+) with Qlogic, the issue was nev

Re: Issues with bxe NIC

2018-02-01 Thread Marius Halden
On Thu, Feb 1, 2018, at 15:17, Marius Halden wrote: > Hi, > > We have two routers running FreeBSD r320487 (BSDRP) with bxe NICs, they > are connected together with a twinax cable and to our ISP with 1Gbit > fiber. The NICs in question are Broadcom BCM57840S (Supermicro AOC-STG- > B4S). > > The

Issues with bxe NIC

2018-02-01 Thread Marius Halden