@gnu.org
Subject: Re: [Discuss-gnuradio] sample time alignment in GRC
On 06/17/2014 09:58 AM, Lapointe, Benjamin - 1008 - MITLL wrote:
Hi All,
I am still having trouble time aligning sample streams from two USRP X310
devices. In GRC I noticed a random time offset from run to run in the
day, June 13, 2014 2:04 PM
*To:* Lapointe, Benjamin - 1008 - MITLL
*Cc:* discuss-gnuradio@gnu.org
*Subject:* Re: [Discuss-gnuradio] sample time alignment in GRC
Make sure that you specify that the 2nd X310 uses external clock and
1PPS, and all of them should use time synch of
"unknown PPS&q
Sent: Friday, June 13, 2014 2:04 PM
To: Lapointe, Benjamin - 1008 - MITLL
Cc: discuss-gnuradio@gnu.org
Subject: Re: [Discuss-gnuradio] sample time alignment in GRC
Make sure that you specify that the 2nd X310 uses external clock and 1PPS, and
all of them should use time synch of
"unkno
Make sure that you specify that the 2nd X310 uses external clock and 1PPS, and all of them should use time synch of
"unknown PPS".
Also, there has been a bug in the scope sink (dunno if fixed) where samples are *not* time-aligned in the scope sink. The except
is that a complex-pair will be t