Len, That's the best guess I've heard so far.
On Sep 10, 2015 4:32 PM, "Mitchell's via CnC-List"
wrote:
> Josh, It may have been the PO's DIY winterizing solution. Our PO had a
> complicated hose system where he pumped air into the head sink faucet to
> bleed the 3 tank water system and piping.
>
Josh, It may have been the PO's DIY winterizing solution. Our PO had a
complicated hose system where he pumped air into the head sink faucet to bleed
the 3 tank water system and piping.
Just a guess!
Len Mitchell
1989 37+
Sent from my mobile device.
___
I hit
>>> upon the idea of not using the port water tank the last time the tanks ran
>>> down, and shut off the valve on the outlet of the tank. That way the weight
>>> of the water in the starboard tank will offset some of the weight of the
>>> stuff to por
dea of not using the port water tank the last time the tanks
>> ran down, and shut off the valve on the outlet of the tank. That way the
>> weight of the water in the starboard tank will offset some of the weight of
>> the stuff to port, which took care of most of the list, and h
only 40
> gaallons of water is not much of a problem when not cruising.
>
>
>
>
>
> Rick Brass
>
> Washington, NC
>
>
>
>
>
>
>
> *From:* CnC-List [mailto:cnc-list-boun...@cnc-list.com] *On Behalf Of *Josh
> Muckley via CnC-List
> *Sent:* Tuesday, S
From: CnC-List [mailto:cnc-list-boun...@cnc-list.com] On Behalf Of Josh Muckley
via CnC-List
Sent: Tuesday, September 08, 2015 2:55 PM
To: C&C List
Cc: Josh Muckley
Subject: Stus-List Water tank x-connect
So I'm doing some water tank work and I've confirmed what I already s
: Stus-List Water tank x-connect
From: cnc-list@cnc-list.com
CC: svpegasu...@gmail.com
On Pegasus all 3 tanks have a common vent that exists at the head sink. I
wouldn't want an external vent for my potable water, due the possibility of sea
water contamination. I fill my tanks sta
Doug MountjoysvPegasusLF38 just west of Ballard, WA.
-- Original message--From: Robert Boyer via CnC-ListDate: Tue, Sep 8,
2015 12:22To: cnc-list@cnc-list.com;Cc: Robert Boyer;Subject:Re: Stus-List
Water tank x-connect
On my LF38, all three tanks have their own individual vent as they should.
rt and see exactly how much
water is left.
I can show pictures of my setup if you want.
Regards,
François Rivard
1990 34+ "Take Five"
Lake Lanier, GA
From: Josh Muckley
To: "C&C List"
Subject: Stus-List Water tank x-connect
Message-ID:
Content-Type: text/plain; c
On my LF38, all three tanks have their own individual vent as they should. The
vent line follows the inlet hose and exits the hull just below each fill
connection on the deck. The original vent lines are 3/8" gray plastic piping.
A good venting system is necessary to get good flow into and out
So I'm doing some water tank work and I've confirmed what I already
suspected. My tanks are cross vented to one another through a low point
loop. It appears that I could in theory fill all my tanks from one deck
fill port despite having a fill port for each of my tanks. I'm thinking
that trackin
11 matches
Mail list logo