On Tuesday 26 June 2007 10:43, Sue Roberts wrote:
> Hello Everyone
>
> This isn't really a question, just a warning to check your
> anisotropic temperature factors both after refinement and after
> deposition at the pdb.
I encourage everyone who is refining, depositing, or inspecting
struct
Hello Everyone
This isn't really a question, just a warning to check your
anisotropic temperature factors both after refinement and after
deposition at the pdb.
We've been having a lot of trouble with anisotropic temperature
factors lately. Here's what's been going on.
We have three d